Operating Instructions Premium HMI
6-21
A help message will appear. For the alarm shown, the message "CHECK OIL LEVEL. IF UNIT IS SHUT DOWN, REPAIR
IMMEDIATELY. OTHERWISE, REPORT ALARM AT END OF THE DAY" will be shown on the display. Check the oil
level and add oil as required, clear the alarm and restart the engine.
To select a different Main Menu item press the NEXT key. To return to the Premium Display press the EXIT key.
Important Alarm Notes
• If an alarm will not clear, it may still exist. If the alarm is not corrected, it will not clear or may be immediately set again.
• If an alarm cannot be cleared from the Main menu, the Clear key will not appear. These alarms must be cleared from the
Maintenance or Guarded Access Menus.
• All alarms must be viewed before any of the alarms can be cleared.
DATALOGGER
The unit can be equipped with an optional DAS Data Logger if desired.
A Start of Trip marker can be sent to the unit ServiceWatch Data Logger and the optional DAS Data Logger (if equipped).
If equipped with the optional DAS Data Logger, the most recent DAS trip record can be printed. The most recent trip is defined
as the trip following the last Start of Trip marker sent to the data logger.
The ServiceWatch Data Logger and DAS Data Logger (if equipped) are accessed using the Data Logger Menu. From the
Premium Display, press the MENU key. (Figure "Menu Key" page 6-15)
The Language Menu or Alarm Menu will appear. Press the NEXT key as required to display the Data Logger Menu. When
the Data Logger Menu is shown press the SELECT key.
Select Key
The first feature that appears is the Start of Trip. To send a Start of Trip to the ServiceWatch Data Logger and DAS Data
Logger (if equipped), press the SELECT key to select the feature, and then press it again to send the Start of Trip. The display
will briefly show START OF TRIP COMPLETE to confirm that a Start of Trip marker was set in the data logger(s).
Start of Trip
NOTE: The start of trip marker is sent to both the ServiceWatch Data Logger and DAS Data Logger (if equipped).
Press the NEXT key to select the PRINT feature. The PRINT screen will appear. Press the SELECT key to print the most
recent trip record.
Select Key
Pressing the EXIT key returns the display to the Main Menu.
HOURMETERS
Hourmeters are displayed using the Hourmeter Menu. Only hourmeters enabled in the Guarded Access Menu will be shown.
From the Premium Display, press the MENU key. (Figure "Menu Key" page 6-15)
The Language Menu or Alarm Menu will appear. Press the NEXT key as required to display the Hourmeter Menu. When the
Hourmeter Menu is shown press the SELECT key. The Hourmeter Display will appear.
Содержание T-1000R
Страница 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Страница 18: ...Specifications 3 4 ENGINE CLUTCH Engagement 600 100 RPM Dynamic Torque 66 fT lb 89 5 N m minimum 1600 RPM ...
Страница 34: ...Maintenance Inspection Schedule 4 10 ...
Страница 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Страница 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Страница 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Страница 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Страница 72: ...Unit Description 5 38 ...
Страница 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Страница 120: ...Operating Instructions Standard HMI 7 18 ...
Страница 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Страница 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Страница 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Страница 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Страница 184: ...Engine Maintenance 9 46 ...
Страница 238: ...Refrigeration Maintenance 10 54 ...
Страница 246: ...Clutch Maintenance 11 8 ...
Страница 258: ...Structural Maintenance 12 12 ...
Страница 264: ...Mechanical Diagnosis 13 6 ...
Страница 265: ...14 Electric Standby Diagnosis ...
Страница 268: ...Electric Standby Diagnosis 14 4 ...
Страница 269: ...15 Refrigeration System Diagnosis ...
Страница 272: ...Refrigeration System Diagnosis 15 4 ...
Страница 280: ...Remote Evaporators 16 8 ...
Страница 282: ...Wiring Diagrams and Wiring Schematics 17 2 ...