Operating Instructions Premium HMI
6-27
Pretrip Test Considerations
When performing a Pretrip Test, the following issues should be considered.
• If running a Pretrip Test on a truck or trailer loaded with dry cargo, insure that proper airflow can occur around the load. If the
load restricts airflow, false test results may occur. Also, TSR-2/3 units have high refrigeration capacity which results in rapid
temperature changes. Sensitive dry cargo may be damaged as a result.
• If running a Pretrip Test on a truck or trailer that has just been washed down, the extremely high humidity inside the truck or
trailer may result in false test results.
• If running a Pretrip Test on a truck or trailer loaded with sensitive cargo, monitor the load temperature during the test as
normal temperature control is suspended during a Pretrip Test.
• Always perform Pretrip Tests with the truck or trailer cargo doors closed to prevent false test failures.
Performing a Pretrip Test
If a Pretrip Test is initiated with the engine shut down a Full Pretrip Test will be performed. If a Pretrip Test is initiated with
the engine or motor running a Running Pretrip Test is performed.
• Before initiating a Pretrip Test, clear all alarm codes.
• To stop a Pretrip Test at any time, turn the unit off. Alarm Code 28 Pretrip Abort will be set. Other alarms may also be set,
depending upon test in progress when the test was terminated.
Pretrip Tests are initiated using the Pretrip Menu. From the Premium Display, press the MENU key. (Figure "Menu Key"
The Language Menu or Alarm Menu will appear. Press the NEXT key as required to display the Pretrip Menu. When the
Pretrip Menu is shown press the SELECT key.
Select Key
If the unit is not running a Full Pretrip Test will be initiated. If the unit is running in either diesel or electric mode a Running
Pretrip will be performed.
Running Pretrip
If all alarms were not cleared a prompt appears as shown. Exit the Pretrip Test, clear all alarms and restart the Pretrip Test.
No Pretrip Prompt
If no alarms are present, the Pretrip Test display appears.
Pretrip Test Display
• The top line of the display indicates the unit is performing the non-running portion of the Pretrip Test.
• The second line measures test progress. The number of tests completed of the total number of tests to be performed is shown.
In Figure the unit is performing Test 1 of 26, Sensor Check.
• The soft keys may be used during the Pretrip Test to select the Hourmeter, Gauge or Sensor menus.
• To stop a Pretrip Test at any time turn the unit off. This will generate Alarm Code 28 Pretrip Abort. Other alarm codes may
also be generated. This is normal when the Pretrip Test is halted before completion.
When the non-running tests are complete the unit will start automatically and continue with the Running Pretrip Test. In the
example in Figure the unit is in the Running Pretrip and is performing Test 21 of 26, Cool Test.
Содержание T-1000R
Страница 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Страница 18: ...Specifications 3 4 ENGINE CLUTCH Engagement 600 100 RPM Dynamic Torque 66 fT lb 89 5 N m minimum 1600 RPM ...
Страница 34: ...Maintenance Inspection Schedule 4 10 ...
Страница 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Страница 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Страница 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Страница 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Страница 72: ...Unit Description 5 38 ...
Страница 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Страница 120: ...Operating Instructions Standard HMI 7 18 ...
Страница 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Страница 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Страница 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Страница 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Страница 184: ...Engine Maintenance 9 46 ...
Страница 238: ...Refrigeration Maintenance 10 54 ...
Страница 246: ...Clutch Maintenance 11 8 ...
Страница 258: ...Structural Maintenance 12 12 ...
Страница 264: ...Mechanical Diagnosis 13 6 ...
Страница 265: ...14 Electric Standby Diagnosis ...
Страница 268: ...Electric Standby Diagnosis 14 4 ...
Страница 269: ...15 Refrigeration System Diagnosis ...
Страница 272: ...Refrigeration System Diagnosis 15 4 ...
Страница 280: ...Remote Evaporators 16 8 ...
Страница 282: ...Wiring Diagrams and Wiring Schematics 17 2 ...