Operating Instructions
42
Starting the Unit
Generator sets are designed to provide power for a
refrigeration unit. Before starting the generator
set, make sure the refrigeration unit power cord is
connected to the generator set electric power
receptacle. To operate the refrigeration unit on
standby power, disconnect the power cord from
the generator set and plug it into the proper power
supply.
1. Turn unit
O
N
/O
FF
switch to On.
2. A series of displays called the Start Sequence
appears on the display as follows:
a. YORK HMI
REV 1.0
b. YORK HMI
SUM: XXX
c. MAIN MENU
DATA
DELAY 11 (or 10, 09, 08, etc. to 01)
The delay screen counts down from 11 to
01 while the controller performs some self
checks.
d. MAIN MENU
DATA
INIT
The controller energizes the air heater for
preheat (if necessary). The preheat buzzer
is energized during the preheat period.
Preheat time ranges from 5 to 120
seconds, depending on the engine
temperature. Preheat may continue until
after the engine starts.
e. MAIN MENU
DATA
FUEL RELAY ON
The controller energizes the fuel relay.
f.
MAIN MENU
DATA
ALTERNATOR OFF
The controller verifies that the alternator
output is off.
g. MAIN MENU
DATA
AIR HEATER ON
This display appears only if the controller
determines that the engine coolant
temperature is low enough to require that
the air heater be energized.
h. MAIN MENU
DATA
STARTER
The engine begins cranking. The air heater
and pre-heat buzzer may remain energized
during the cranking period. The air heater
may also remain energized for 30 seconds
after the engine starts.
i.
MAIN MENU
DATA
RPM CHECK
If the engine RPM does not exceed 50
RPM during the first 4 seconds of
cranking, or if the engine does not start
after 30 seconds of cranking, the cranking
cycle terminates.
j.
MAIN MENU
DATA
SPEED MEAS
This display appears only on units
equipped with the EcoPower option while
the controller checks the low engine
speed. The engine runs in low speed until
the engine temperature reaches 32 C
(90 F).
k. MAIN MENU
DATA
DELAYED OUTPUT
This display appears while the controller
delays energizing the alternator output for
approximately 15 seconds. If the DEL
COLDSTART feature in the Configuration
Menu is set to ON, the alternator output
remains off until the engine temperature
reaches 32 C (90 F).
WARNING: With the unit On/Off switch
in the “ON” position, the unit may start at
any time without prior warning.
Содержание SGCO 3000
Страница 4: ......
Страница 12: ...SGCO 3000 Genset Addendum 12...
Страница 14: ...Genset Model Features 14...
Страница 22: ...Service Guide 22...
Страница 32: ...Unit Description Features Options 32...
Страница 78: ...Operating Instructions 78...
Страница 86: ...Electrical Maintenance 86...
Страница 114: ...Engine Maintenance 114...
Страница 124: ...Alternator Operation and Diagnosis 124...
Страница 130: ...Structural Accessory Maintenance 130...
Страница 138: ...Index 138...
Страница 140: ...Electrical and SG Menu Flow Diagrams 140...
Страница 141: ...141 SGCO 3000 Wiring Diagram Page 1 of 1...
Страница 142: ...142 SGCO 3000 Schematic Diagram Page 1 of 1...