Specifications
24
Electrical Control System
Controls
SG+ microprocessor controller
Voltage
12.5 Vdc (nominal)
Battery
12 volts, group C31, 925/950 Cold Cranking Amps at
-18 C (0 F)
Fuse SI1
30 Amp
Fuse SI2
30 Amp
Fuse SI3
10 Amp
Electrical Components
NOTE: Disconnect components from unit circuit to check resistance.
Current Draw (Amperes) at 12.5 Vdc
Resistance (Ohms)
Air Heater
89
0.14
Fuel Solenoid:
Pull-in
Hold-in
35 to 45
0.5 to 1.0
0.2 to 0.3
24 to 29
Speed Solenoid (EcoPower Option only)
2.9
4.3
Starter Motor
400 (cranking)
140 (bench test)
Controller Default Settings
Setting – Menu Location
Default Setting
Tank Size – Commands/System Setup
125
Date/Time – Commands/System Setup
Software Date
ID Number – Commands/System Setup
00000000
C/F Mode – Misc. Functions
F
LOP (Low Oil Pressure) Restart – Configuration
Off
DEL (Delayed) Coldstart – Configuration
On
HM1 (Hour Meter 1) Threshold – Configuration
0
HM2 (Hour Meter 2) Threshold – Configuration
0
ENG (Engine) Off Hours – Configuration
0
Factory Reset – Configuration
Off
APU Connected – Configuration
Off
Output Voltage – Configuration
460
Fuel Sensor – Configuration
Off
Fuel Level – Configuration
0
Crank Restarts – Configuration
3
Telematic – Configuration
Off
NOTE: The controller returns the Date/Time to the default setting when the battery is disconnected.
Содержание SGCO 3000
Страница 4: ......
Страница 12: ...SGCO 3000 Genset Addendum 12...
Страница 14: ...Genset Model Features 14...
Страница 22: ...Service Guide 22...
Страница 32: ...Unit Description Features Options 32...
Страница 78: ...Operating Instructions 78...
Страница 86: ...Electrical Maintenance 86...
Страница 114: ...Engine Maintenance 114...
Страница 124: ...Alternator Operation and Diagnosis 124...
Страница 130: ...Structural Accessory Maintenance 130...
Страница 138: ...Index 138...
Страница 140: ...Electrical and SG Menu Flow Diagrams 140...
Страница 141: ...141 SGCO 3000 Wiring Diagram Page 1 of 1...
Страница 142: ...142 SGCO 3000 Schematic Diagram Page 1 of 1...