7.17 Main Transformer Test
Disconnect the secondary of the Main Transformer T2 from the rectifier bridge and measure output voltage between
the two transformer output connections as follows:
COARSE VOLTAGE SELECTION
FINE VOLTAGE SELECTOR
VOLTAGE AC (approx.)
SWITCH SETTING
SWITCH SETTING
1
1
13.3
1
2
13.9
1
3
14.4
1
4
15.1
2
1
15.8
2
2
16.6
2
3
17.4
2
4
18.3
3
1
19.3
3
2
20.4
3
3
21.6
3
4
23.1
4
1
24.6
4
2
26.5
4
3
28.7
4
4
31.2