7.16 Rectifier Assembly Test
1. Disconnect one of the Main Transformer connections from the rectifier assembly.
2. Disconnect and isolate wires from the Negative output of the Rectifier Assembly See Figure
7
-3.
3. Disconnect JB connector from MAIN PCB 1.
4. Using a meter check the diode readings between the following points:
Forward biased diode junction:
Positive meter probe on rectifier plates 2 and 3 to plates 1 & 4
Negative meter probe on rectifier plates 1 & 4 to plates 2 & 3
A
r
t # A-07575
1
2
3
4
Remove a
n
d i
s
olate f
r
om
r
ectifie
r
a
ss
embly
Figure 7-3: Rectifier Assembly Test
Double forward biased junction:
Positive meter probe on rectifier plates 1 & 4 to positive rectifier output terminal (Picture needed)