CoolShell 3U Generation 2 Installation Manual
Version 1.1
1-12
Themis Computer
1.5
Specifications
1.5.1
General
Table 1-1
lists the general specifications for the CoolShell 3U.
1.5.2
Environmental
The CoolShell 3U is designed to meet the environmental requirements listed in
Table 1-2
.
Table 1-1.
General Specifications
Parameter
Weight
a
a—All weight in this table is an approximation. Actual weight is dependent on specific
system configuration
CoolShell 3U Weight—Average
CPU Blade
I/O Blade
Media Module
Power Supply (PS)
Subrack
Storage Expansion Subsystem
34.26 pounds (1 PS
b
)
to 41.2 (2 PS) pounds
8.5 pounds
8.5 pounds
4.5 pounds
2.76 pounds
10 pounds
6.9 pounds
b—Weighed with one power supply installed—system is capable of redundant power
supplies if desired
Table 1-2.
Environmental Specifications
Parameter
Operating
Non-Operating
Temperature
0° to 55° C
–40° to 80° C
Humidity (non-condensing)
0% to 95%
0% to 95%
Atmospheric Pressure
87.0 to 108.4 kPa
57.2 to 108.4 kPa
Altitude
0 to 10,000 feet above sea level
0 to 40,000 feet above sea level
Shock
35 g @ 25ms
35 g @ 25ms
Vibration
3G (rms), 4 Hz to 28 Hz (MIL167)
3G (rms), 4 Hz to 28 Hz (MIL167)
Airflow
280 CFM
N/A
Содержание CoolShell 3U
Страница 22: ...xiv Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 24: ...xiv Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 70: ...A 14 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 118: ...B 48 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 122: ...C 4 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1 Figure C 2 X9DRi F Block Diagram...
Страница 130: ...C 12 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 156: ...CoolShell 3U Generation 2 Installation Manual Version 1 1 Index 6 Themis Computer...