CoolShell 3U Generation 2 Installation Manual
Version 1.1
B-26
Themis Computer
B.3.11.6
Parity
A parity bit can be sent along with regular data bits to detect data transmission
errors. Select Even if the parity bit is set to 0, and the number of 1’s in data bits is
even. Select Odd if the parity bit is set to 0, and the number of 1’s in data bits is odd.
Select None if you do not want to send a parity bit with your data bits in transmis-
sion. Select Mark to add a mark as a parity bit to be sent along with the data bits.
Select Space to add a Space as a parity bit to be sent with your data bits. The options
are
None
(default), Even, Odd, Mark, and Space.
0.0.0.1 Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard
serial data communication. Select 2 Stop Bits if slower devices are used. The options
are
1
(default) and 2.
B.3.11.7
Flow Control
This feature allows the user to set the flow control for Console Redirection to pre-
vent data loss caused by buffer overflow. Send a “Stop” signal to stop sending data
when the receiving buffer is full. Send a “Start” signal to start sending data when the
receiving buffer is empty. The options are
None
(default) and Hardware RTS/CTS.
B.3.11.8
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 ter-
minals. The options are
Enabled
(default) and Disabled.
B.3.11.9
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text mes-
sage to a remote server. The options are
Disabled
(default) and Enabled.
B.3.11.10
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled
and
Enabled
(default).
B.3.11.11
Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console Redirec-
tion for legacy OS support. The options are
80x24
(default) and 80x25.
Содержание CoolShell 3U
Страница 22: ...xiv Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 24: ...xiv Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 70: ...A 14 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 118: ...B 48 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 122: ...C 4 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1 Figure C 2 X9DRi F Block Diagram...
Страница 130: ...C 12 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 156: ...CoolShell 3U Generation 2 Installation Manual Version 1 1 Index 6 Themis Computer...