The AC input rating for the CS-3U, 850W (max) power supply units are as fol-
lows: 100-240VAC, 12 A max, 50/60 Hz.
•
The unit is completely disconnected from the power source only when all
power cords are disconnected from the power source. Therefore the power
cords and its connectors must always remain easily accessible.
•
Do not set up the device in the proximity of heat sources or in a damp location.
Make sure the device has adequate ventilation.
•
Manufacturer recommended ambient temperature is 21°C
•
All connection cables must be screwed or locked to the chassis housing.
•
The device is designed to be used in horizontal position only.
•
The device is no longer safe to operate when
— the device has visible damage or
— the device no longer functions.
•
In these cases, the device must be shut down and secured against unintentional
operation.
•
Repairs/service may only be carried out by a Themis Computer qualified ser-
vice technician.
•
Do not open the chassis, or perform services/repairs when the equipment is
powered on, due to electrical shock hazard.
•
The device may only be opened for the installation and removal of extension
(PCI) cards, memory modules, storage drives, fan housings, power supplies,
and the lithium battery—all in accordance with the instructions given in this
manual.
•
If extensions are made to the device, the legal stipulations and the device spec-
ifications must be observed.
•
The device must be switched off when removing the top cover; for example,
before installing extension (PCI) cards.
Operation of Laser Source Devices
DVD/CD-ROM drives contain laser light-emitting diodes (classified in accordance
with IEC 825-1:1993: LASER CLASS 1) and, therefore, must not be opened.
If the enclosure of such a drive is opened, invisible laser radiation is emitted. Do
Содержание CoolShell 3U
Страница 22: ...xiv Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 24: ...xiv Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 70: ...A 14 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 118: ...B 48 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 122: ...C 4 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1 Figure C 2 X9DRi F Block Diagram...
Страница 130: ...C 12 Themis Computer CoolShell 3U Generation 2 Installation Manual Version 1 1...
Страница 156: ...CoolShell 3U Generation 2 Installation Manual Version 1 1 Index 6 Themis Computer...