114
6.9 Control input S1 (channel A light)
Control input S1 for manually switching lighting (channel A lighting) on/off is automatically recog
-
nized by the push-button or switch.
●
Several push-buttons/switsches are possible on the S1 control input
●
Only use light buttons with zero wire connections
Value range
Automatic recognition of push-button or switch. A signal indicated as less than 0.7 sec is recognised as a
push-button. Longer signals are evaluated as switches.
auto
The type of signal transmitter used can be fixed set for adjustment to user
behaviour. Automatic detection is deactivated.
Additional NC contact or NO contact can be selected for the push-button.
switch
Push-button (NO contact)
Push-button (NC contact)
switch
P-button N/O
P-Button N/C
6.10 Detection sensitivity
The detector has 5 sensitivity levels. The basic setting is the middle
level (3). A level can be selected with the SendoPro management
remote control. Sensitivity also applies during the test-modes.
By selecting the operation mode test presence, the set sensitivity
level is not changed.
The parameter can be changed during test presence.
Level
Sensitivity
1
less sensitive
2
Interim value
3
Standard
4
Interim value
5
very sensitive