8-8-14. Output switching (
:
EXT
:
OUTP)
This command selects output On/Off with external contacts.
Setting
:
EXT
:
OUTP <value>
<value> is as shown below:
0: Control from the panel or through communication
1: Output On/Off with external contacts
Application
example
:
EXT
:
OUTP 1
Selects output On/Off with external contacts.
Query
:
EXT
:
OUTP?
Inquires about the setting.
Response
example
1
Indicates that output On/Off with external contacts is working.
“?” has the same function as <value>.
Remark
This command causes an error during sequence operation
(RUN).
8-8-15. Off timer ON/OFF (
:
TIMER
:
MOD)
This command activates or deactivates the Off Timer.
Setting
:
TIMER
:
MOD <value>
<value> is as shown below:
0: Deactivates the Off Timer.
1: Activates the Off Timer.
Application
example
:
TIMER
:
MOD 1
Activates the Off Timer.
Query
:
TIMER
:
MOD?
Inquires about the setting.
Response
example
1
Indicates that the Off Timer is working.
“?” has the same
function as <value>.
Remark
This command causes an error during sequence operation
(RUN).
Содержание PSF-1200L
Страница 5: ......
Страница 11: ...2 400W 2 Channel Type PSF 400L2 400W Type PSF 400L 800W Type PSF 800L 800W Type For Current Extention PSF 800LS...
Страница 18: ...9...
Страница 115: ...106 PSF 800LS Dust filter Dust filter Front grill Front grill Pull frontward while pressing here...
Страница 117: ...108 290 35 7 6 5 82 7 209 9 10 9 124 The handle is available by option Fig 11 2 Outside Dimensions of PSF 800LS...
Страница 121: ...7F Towa Fudosan Shin Yokohama Bldg 2 18 13 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan http www texio co jp...