8-8-4. OCP setting (
:
CURR
:
PROT)
This command sets or inquires about the OCP (over-current protection)
value.
Setting
:
CURR
:
PROT<value>
Sets the OCP value of a one-output model.
:
CURR
:
PROT
:
A<value>
Sets the OCP value of CHA.
:
CURR
:
PROT
:
B<value>
Sets the OCP value of CHB.
The <value> range in single-unit operation is as shown below:
PSF-400L & PSF-400L2: 1.00 to 42.00
PSF-800L: 1.00 to 84.00
Two decimal places are valid.
The setting range changes in power extension master-slave
(parallel) operation.
Resolution in parallel operation: 100mA
Setting range: 0.0 to (total current x 1.05)
Application
example
:
CURR:PROT 10.10
Sets the OCP value of a one-output model to 10.10A.
Query
:
CURR
:
PROT?
Inquires about the set OCP value of a one-output model.
:
CURR
:
PROT
:
A?
Inquires about the set OCP value of CHA.
:
CURR
:
PROT
:
B?
Inquires about the set OCP value of CHB.
Response
example
10.10
Indicates that the set OCP value is 10.10A.
Remark
In tracking operation, setting of the CHA reflects upon the CHB
and CHB setting causes an execution error.
Содержание PSF-1200L
Страница 5: ......
Страница 11: ...2 400W 2 Channel Type PSF 400L2 400W Type PSF 400L 800W Type PSF 800L 800W Type For Current Extention PSF 800LS...
Страница 18: ...9...
Страница 115: ...106 PSF 800LS Dust filter Dust filter Front grill Front grill Pull frontward while pressing here...
Страница 117: ...108 290 35 7 6 5 82 7 209 9 10 9 124 The handle is available by option Fig 11 2 Outside Dimensions of PSF 800LS...
Страница 121: ...7F Towa Fudosan Shin Yokohama Bldg 2 18 13 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan http www texio co jp...