82
8-8-5. Output power setting (
:
POW)
This command sets or inquires about the output power.
Setting
:
POW <value>
Sets the output power of a one-output model.
:
POW
:
A<value>
Sets the output power of CHA.
:
POW
:
B<value>
Sets the output power of CHB.
The <value> range in single-unit operation is as shown below:
PSF-400L & PSF-400L2: 10 to 410
PSF-800L: 10 to 820
The integer is valid.
The setting range changes in power extension master-slave
(parallel) operation.
Setting range: 0.0 to (total power x 1.025)
Application
example
:
POW 100
Sets the output power of a one-output model to 100W.
Query
:
POW?
Inquires about the set output power of a one-output model.
:
POW
:
A?
Inquires about the set output power of CHA.
:
POW
:
B?
Inquires about the set output power of CHB.
Response
example
100
Indicates that the set output power is 100W.
Remark
In tracking operation, setting of the CHA reflects upon the CHB
and CHB setting causes an execution error.