72
7.
Choose the
Off-Time
in seconds.
The off-time setting determines how long the
load is turned off between the end of the
current step and the start of the next step.
The off-time is defined as the total test time
minus the on-time.
Off-Time
Off, 0.1 ~ 60 seconds
8.
Choose the
P/F-Time
(pass/fail time) in seconds.
The P/F-Time refers to the P/F delay time. This
delay time includes the 0.06 P/F start test time,
as shown in the timing diagram on page 70.
P/F-Time
Off, 0.0 ~ 119.9 seconds
9.
Set the
Short-Time
in seconds.
Has the same action as pressing the short key.
See page 36 for details about shorting the load.
Short-Time
Off, 0.1 seconds ~ On-Time
10.
Repeat steps 3 to 9 for all the steps in the
program.
A maximum of 16 steps per program can be
created.
Steps that are not configured are set
to “Skip”
by default.
11.
Press
Save[F3]
to save the program and all the
steps in the program.
The program will be saved to internal memory.
See the Save/Recall chapter on details on how
to save to Setup memory.
Recall Default
Pressing
Recall Default[F4]
will recall the default
settings for each program/step. See page 127
for details.