107
4-1-5. External Resistance Control
– Operation
Description
External resistance control can be used to control
the current, voltage, resistance and power for CC,
CR, CV and CP modes. Configuration for each
operating mode is the same.
CC Mode
Proportional Control:
Input current = rated current × (external
resistance/10).
Inverse Control:
Input current = rated current × (1 - external
resistance/10).
Input
Current
External
Resistance
Rated
Current
0
Ω
10k
Ω
Proportional
control
Inverse control
CR Mode
Proportional Control:
Input conductance = rated conductance ×
(external resistance/10).
Inverse Control:
Input conductance = rated conductance ×
(1 - external resistance/10).
Input
Conductance
External
Resistance
Rated
Conductance
0
Ω
10k
Ω
Proportional
control
Inverse control