40
Example
Level
Time
Set
Level
Timer1 Timer2 Timer1
Dynamic Mode:
Dyna. Level = Percent
2-2-3. Select the Switching Time Configuration for Dynamic
Mode
Description
The switching time for dynamic mode can be
configured to switch between two preset on-
times (Timer1, Timer2) or by setting a switching
frequency and duty cycle.
Operation
1.
Press
Main
>
Configure[F5]
>
Other[F2]
and
set the
Dyna. Time
setting.
Range:
T1/T2, Freq. Duty
2-2-4. Slew Rate
Description
The current slew rate can be set for CC and CR
mode. The slew rate setting is used to limit the
change in current when switching.
For static mode, only a single slew rate can be
set.
Operation
1.
Make sure the load is off.
2.
Press
Main
.
3.
Set the slew rate(s) using the scroll wheel and
number pad.
For static mode, only a single slew rate can be
set.
For dynamic mode, set both the rising and
falling slew rates.
Take the timer settings into consideration when
setting the slew rates.