Installation
INS 034-9
9
2.4.1.1
PCB Terminals and Fuses
Terminal
Description
Note
AC (2)
Transformer AC in
NOT for mains supply
BATT-
Standby Battery negative
BATT+
Standby Battery positive
S
SAB Strobe switched negative
D
SAB negative Supply
C
SAB negative Tamper return
B
SAB Bell switched negative
A
SAB positive Supply
L/S (2)
Loudspeaker
AUX-
Auxiliary Supply negative
use for detectors
AUX+
Auxiliary Supply positive
use for detectors
SW+
Switched Positive output
TAMP
Global Tamper loop
Z1 - Z8
Zone loops
T
Keypad data
R
Keypad data
AUX-
Auxiliary Supply negative
use for RKP(s)
AUX+
Auxiliary Supply positive
use for RKP(s)
1)
A spare mains fuse is supplied in a clip adjacent to the mains terminal block.
2)
Spare PCB fuses are supplied in a press-seal bag.
Fuse
Description
Rating
F1
Battery fuse
F1A, 250V, 20mm
F2
Bell & Strobe fuse
F1A, 250V, 20mm
F3
L/S & Detector Auxiliary fuse
F500mA, 250V, 20mm
F4
RKP Auxiliary fuse
F500mA, 250V, 20mm
F5
Power Supply Output fuse
F1.6A, 250V, 20mm
1)
When replacing a fuse always observe the specified rating and type - failure to do so
is dangerous and will invalidate the warranty. Fuses should comply with IEC 127.
2)
The press-seal bag must NOT be stored inside the panel.
2.4.2
Wiring the External Sounder and Strobe
Always consult the manufacturer's connection instructions. The external sounder
and strobe are connected to the five terminals labelled SAB on the control panel
as follows:
Terminal
Description
A
Permanent Positive Supply (+12V)
B
Switched Negative to Activate Sounder
C
Negative Tamper Return
D
Permanent Negative Supply (0V)
S
Switched Negative to Activate Strobe