Programming
26
INS 034-9
3.6
Re-Loading the Factory Settings
!)
From the Programming Menu,
enter
!)
.
All the zone lights will turn off.
Press
,
.
The system will chime to confirm that all the factory settings have been
re-loaded into the Non Volatile Memory. The system will then automatically revert
to the Programming Menu and all the zone lights will illuminate.
If the Engineer code has been lost, provided it has not been locked (section 3.2.2,
page 21)
power down the system
(mains and battery).
Restore power
. All the
indicator lights will illuminate for 10 seconds.
Press
-
, or SLOWLY press
and release the panel lid tamper spring 3 times, before the indicator lights turn off.
The factory settings have now been re-loaded into the Non Volatile Memory.
1)
Unlocking a locked Engineer code that has been lost is subject to a
minimum charge.
2)
Re-loading factory settings will not clear the Event Log (see section 3.14.1,
page 34).
3)
The system will bleep each time the panel lid tamper spring is pressed and
released during the first 10 seconds after power up.
3.7
Programming the Switched Positive Output
!*
From the Programming Menu,
enter
!*
.
The zone light of the function currently
selected will illuminate.
Press the number of the function required
from the
following list.
Press
,
.
The system will chime to confirm the new function
has been accepted. The system will automatically revert to the Programming
Menu and all the zone lights will illuminate.
Number
SW+ Function
1
Set Positive (latching detectors)
2
Alarm Positive with Latching Sensor Reset (FTA detectors)
3
Latching Shock Sensor Auto-Reset (old style latching shock sensors)
4
Tamper
5
Mains Fail
6
Set Positive with Latching Sensor Reset (latching detectors)
7
Walk Test
8
Entry/Exit
If connecting multiple detectors to one zone then:
!
Latching detectors will indicate which detector(s) activated during an alarm.
!
First to Alarm (FTA) detectors will indicate which detector caused an alarm and
which detectors were then activated during the alarm.
Option 3 would typically be used with older designs of latching shock sensor
which do not have a Latch input and must be powered down to clear the Latch
indication. In this case the detectors would be powered from the SW+ output.