Programming
32
INS 034-9
3.11.1
Programming the Date
#&
From the Programming Menu,
enter
#&
.
All the zone lights will turn off.
Enter
the current date as a 6 digit number; Day, Day, Month, Month, Year, Year
(e.g.
to program the 1st of June 1998 enter
!"!'(*
). Zone lights 1, 2, 3, 4, 5
and 6 will illuminate in turn as each digit of the new date is entered.
Press
,
.
The system will chime to confirm the new date has been accepted. The system will
then automatically revert to the Programming Menu and all the zone lights will
illuminate.
3.11.2
Programming the Time
#'
From the Programming Menu,
enter
#'
.
All the zone lights will turn off.
Enter
the current time as a 6 digit number; Hour, Hour, Minute, Minute, Second,
Second
using 24 hour format (e.g. to program 7 minutes and 3 seconds past 2pm
(14:07:03) enter
"%!)!$
). Zone lights 1, 2, 3, 4, 5 and 6 will illuminate in
turn as each digit of the new time is entered.
Press
,
.
The system will chime
to confirm the new time has been accepted. The system will then automatically
revert to the Programming Menu and all the zone lights will illuminate.
3.12
Programming the Service Timers
The
Veritas
features three service timers designed to facilitate the convenient
support of service contracts.
Disclaimer:
It is the responsibility of the Installer to obtain prior written agreement from the
Customer regarding any use of a Service Timer. Texecom accept no liability
whatsoever for any dispute resulting from the use of Service Timers.
Service Timer One is designed to be used as a reminder. When it expires it turns
on high level chime on all eight zones the first time the panel is set/unset.
Service Timer Two is designed to be used as a nuisance. When it expires it turns
on high level chime on all eight zones every time the panel is set/unset.
Service Timer Three is designed to be used as a lockout. When it expires the
panel will require an Engineer Reset (section 3.2.5, page 23).
Any one, any two, or all three timers can be programmed for the same or different
dates. To disable a service timer simply program an invalid or expired date.
Expired service timers are automatically cleared when an Engineer code is
entered.
1)
It is essential to program the current date (
#&
) and time (
#'
) for correct
operation of the service timer(s).
2)
Programming the service timers (
#)
,
#*
,
#(
) is prevented unless the
current date (
#&
) has first been programmed.
3)
The user can turn off chime globally or on individual zones but where still
selected it will remain at high level until reprogrammed by an Engineer.
4)
When Service Timer Three expires it will turn chime off.