Programming
24
INS 034-9
3.2.6
Push To Set
Push to Set is intended to reduce false alarms due to user error when full setting
the system. The user starts full set in the usual way and leaves the premises.
However the system will ONLY set when an external push button is pressed.
1)
The Zone Type of the zone to which the external push button is connected
must be programmed as Push to Set (section 3.9, page 27):
a)
If this zone is set to chime (see User Guide) then the push button can
double up as a door bell.
b)
The external push button should be waterproof unless it is located in an
enclosed porch.
2)
Push to Set does not operate in part set.
3)
Push to Set satisfies the requirements of NACP 14, Issue 1, Section 2.1.2.
3.3
Programming the Number of Alarm Activations
!%
From the Programming Menu,
enter
!%
. All the zone lights will turn off.
Enter
the desired number of Alarm Activations as a two digit number
(e.g. for three
Activations, enter
!$
). Zone 1 light will illuminate when the first digit is entered.
Zone 2 light will illuminate when the second digit is entered.
Press
,
. The
control panel will chime to confirm that the new number of Activations has been
accepted. The system will then automatically revert to the Programming Menu and
all the zone lights will illuminate.
The total number of Activations should not be less than 01.
3.4
Testing the Sounders, Strobe and SW+
!&
From the Programming Menu,
enter
!&
.
All the zone lights will turn off. The
system outputs may be tested as follows:
Key
Function
'
Invoke bell box hold-off mode
&
Toggle the SW+ output
%
Toggle the internal sounder at high level (alarm level)
$
Toggle the internal sounder at low level (entry/exit level)
#
Toggle the strobe output
"
Toggle the external sounder (bell) output
!
Turn off all of the above