Programming
INS 034-9
29
3.9.1.6
Entry/Exit
'
Opening a zone with this Zone Type when the system is set will cause the control
panel to start entry mode. This Zone Type would typically be used for a front door
magnetic contact or, if one is not fitted, a hall PIR.
The Final Door Set option (section 3.2.2, page 21) will cause the exit time to
be reduced to 3 seconds when an Entry/Exit zone is closed during exit mode.
This option would typically be used only when there is a magnetic contact on
the front door.
3.9.1.7
Personal Attack
)
This Zone Type is designed specifically for panic buttons. Zones with this Zone
Type are monitored constantly even when the panel is unset. If activated, they will
cause an immediate alarm, sounding both the internal and external sounders.
3.9.1.8
Keyswitch
*
This Zone Type is designed specifically for key switches. Zones with this Zone
Type are monitored constantly. The key switch can be used to full set, unset,
silence an alarm and reset the system.
1)
Ensure that there are no 24 Hour zones (Fire, PA and Tamper) in fault when
using a key switch to reset the system.
2)
The state of a Keyswitch zone (open or closed) is unimportant, it is the
change in state (from open to closed, or vice versa) which is monitored.
3)
Keypad PA is entered from a keypad and therefore cannot be reset by a key
switch but only by entry of a valid User code.
3.9.2
Programming the Zone Type
Each of the eight Zone Types has an associated Zone Type number which is used
when programming the Zone Type of a zone:
Zone Type Number
Zone Type
1
Push to Set
2
Inhibited Entry
3
Guard
4
Fire
5
Tamper
6
Entry/Exit
7
Personal Attack (Panic)
8
Keyswitch
To program the Zone Type of any zone
press
"
followed by the zone number
.
The zone light of the Zone Type number currently selected will illuminate.
Press
the Zone Type number required. Press
,
.
The system will chime to
confirm the new Zone Type has been accepted. The system will then automatically
revert to the Programming Menu and all the zone lights will illuminate.