![Texecom Veritas 8 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/texecom/veritas-8/veritas-8_installation-manual_1097259025.webp)
Programming
INS 034-9
25
1)
The zone light corresponding to each output will illuminate when it is on.
2)
Several Texecom bell boxes feature a unique, patented "Engineer Hold-Off
Mode" which disables Self-Activate on Lid Tamper to facilitate convenient
servicing. Option
'
will cause the strobe output to pulse 3 times to invoke
Hold-Off Mode. Zone 2 light will flash to indicate the strobe pulsing after
which Zone 6 light will illuminate to indicate that Hold-Off Mode has been
invoked. (See bell box instructions for more details).
Press
-
to return to the Programming Menu. All the zone lights will
illuminate.
3.5
Walk Testing
!'
,
"(
The control panel has two Walk Test modes, Latching and Non-Latching. During
Walk Test when any zone is opened the corresponding zone light will illuminate.
When the zone is closed the zone light will go out in Non-Latching Walk Test, but
will remain on in Latching Walk Test.
From the Programming Menu,
enter
!'
to select Non-Latching Walk Test, or
"(
to select Latching Walk Test.
Initially all the zone lights will turn off and the
control panel will sound the quiet exit tone. When any zone is opened, the
corresponding zone light will illuminate. The control panel will, in addition, sound a
repeating series of bleeps corresponding to the open zone number (i.e. Zone 1
bleeps once, Zone 2 bleeps twice, etc.). If more than one zone is open, the bleeps
will correspond to the highest zone number (e.g. if Zone 2 and Zone 6 are open,
the control panel will bleep 6 times).
Conduct a Walk Test by triggering each of the system's detection devices in turn
and check that the control panel registers the corresponding zone as open.
If the Tamper light is on and the panel bleeps 9 times an extended display reveals
more information about the source of the tamper fault(s). To toggle between the
normal display and the extended display
press
.
. The extended display is
distinguished from the normal display by the Unset light being off. In the extended
display the zone lights are interpreted as follows:
Zone Light
Description
1
Bell Tamper (including Global System Tamper)
2
Not Applicable
3
Lid Tamper (including RKP Lid Tamper)
4
Not Applicable
5
RKP Off-Line
6
Not Applicable
7
Not Applicable
8
Not Applicable
To terminate Walk Test
press
-
.
The system will return to the Programming
Menu and all the zone lights will illuminate.