![Texecom Veritas 8 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/texecom/veritas-8/veritas-8_installation-manual_1097259020.webp)
Programming
20
INS 034-9
3
Programming
Programming is usually unnecessary as the factory settings have been carefully
selected to suit most installations without alteration. However all functions are fully
programmable for Complete Control.
3.1
The Programming Menu
The Programming Menu can only be accessed when the control panel is unset.
Enter your 4 digit Engineer code (factory set to
"#$%
). Press
,
.
All
the zone lights will illuminate. The various programming options are then selected
by entering a 2 digit Option code
++
. The Programming Procedure (section 1.1,
page 4) then depends upon the programming option selected as detailed in the
following sections. On completion, each programming option reverts to the
Programming Menu, allowing other programming options to be accessed. To exit
the Programming Menu
press
-
, the system will revert to unset.
1)
To abort programming at any stage (and preserve the original setting) press
-
, the system will revert to the Programming Menu.
2)
24 Hour zones (Fire, PA and Tamper) are disabled when the Programming
Menu is accessed via an Engineer code.
3)
To omit zones, set chime or change the User code, refer to the User Guide.
4)
The system programming is retained even in the event of complete loss of
power.
3.2
Programming the Miscellaneous Selections
There are four sets of Miscellaneous Selections which control the behaviour of
various system functions.
3.2.1
Miscellaneous Selections Zero
!!
From the Programming Menu,
enter
!!
.
The zone lights of the options currently
selected will illuminate.
Press the appropriate numbered button(s) to select or
de-select the corresponding option(s) as shown on the display. Press
,
.
The system will chime to confirm that the new options have been accepted. The
system will then automatically revert to the Programming Menu and all the zone
lights will illuminate.
Option
Miscellaneous Selections Zero
Factory Setting
1
Cancel Strobe with Bell
Off
2
Keypad PA (pressing
$
and
(
together causes PA alarm)
On
3
Single Button Setting
On
4
Silent Part Set Confirmation Tone
Off
5
EN50131-1 Requirements
Off
6
Time Limit Engineer Access
Off
7
Reset Button Cancels Setting
On
8
Old Style
Veritas
Sounds (must be selected for older version remote keypads)
Off