TVP4020
Programmers Reference Manual
Graphics Programming
75
5.5.4
Registers
The LBReadMode register is as shown below:
0
8
16
24
31
Reserved
PP2
Reserved
PP1
PP0
Partial product selection
ReadSource enable
ReadDestination enable
Data Type
Window origin
Patch Enable
Figure 5.12
LBReadMode Register
PatchEnable, when set, enables normal patch addressing of the
localbuffer. This typically results in more efficient memory bandwidth
utilization.
The Partial Product fields PP0, PP1, and PP2 define the width of the
localbuffer. They are described in Appendix C.
ReadSourceEnable and ReadDestinationEnable control localbuffer
reads of the destination address and source address respectively.
DataType controls the format of localbuffer data, and WindowOrigin
specifies if the window origin is Top Left or Bottom Left.
0
8
16
24
31
Reserved
Write Enable
Figure 5.13
LBWriteMode Register
The localbuffer format must be specified for both reads and writes using
the LBReadFormat and LBWriteFormat registers. Normally these
registers are set to identical values. It may be useful to set them to
different values when, say, copying between two windows using different
depth widths.
Содержание TVP4020 PERMEDIA 2
Страница 1: ...Texas Instruments TVP4020 PERMEDIA 2 Programmer s Reference Manual Issue 4 ...
Страница 47: ...Memory I O and Organization TVP4020 Programmers Reference Manual 38 Texture address TextureBaseAddress T W S ...
Страница 284: ...TVP4020 Programmers Reference Manual A Gouraud Shaded Triangle 275 ...
Страница 292: ...TVP4020 Programmers Reference Manual Register Tables 283 ...
Страница 314: ...TVP4020 Programmers Reference Manual Index 305 ...
Страница 315: ...Index TVP4020 Programmers Reference Manual 306 Index ...
Страница 323: ...Index TVP4020 Programmers Reference Manual 314 ...