c
= 25 °C, V
DDS
= 3.0 V, f
RF
= 2440 MHz with
DC/DC enabled and high power PA connected to V
DDS
unless otherwise noted.
All measurements are performed at the antenna input with a combined RX and TX path, except for high power PA which is
measured at a dedicated antenna connection. All measurements are performed conducted.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Selectivity, ±6 MHz
Wanted signal at –72 dBm, modulated interferer at ≥ ±6
MHz, BER = 10
–3
dB
Selectivity, ±7 MHz
Wanted signal at –72 dBm, modulated interferer at ≥ ±7
MHz, BER = 10
–3
dB
Selectivity, Image frequency
Wanted signal at –72 dBm, modulated interferer at image
frequency, BER = 10
–3
35
dB
Selectivity, Image frequency ±1
MHz
Note that Image fre 1 MHz is the Co- channel
–1 MHz. Wanted signal at –72 dBm, modulated interferer
at ±1 MHz from image frequency, BER = 10
–3
dB
1 Mbps (LE 1M)
Receiver sensitivity
Differential mode. BER = 10
–3
–96
dBm
Receiver saturation
Differential mode. BER = 10
–3
> 5
dBm
Frequency error tolerance
Difference between the incoming carrier frequency and
the internally generated carrier frequency
> (–350 / 350)
kHz
Data rate error tolerance
Difference between incoming data rate and the internally
generated data rate (37-byte packets)
> (–650 / 750)
ppm
Co-channel rejection
Wanted signal at –67 dBm, modulated interferer in
channel, BER = 10
–3
–6
dB
Selectivity, ±1 MHz
Wanted signal at –67 dBm, modulated interferer at ±1
MHz, BER = 10
–3
dB
Selectivity, ±2 MHz
Wanted signal at –67 dBm, modulated interferer at ±2
MHz,BER = 10
–3
dB
Selectivity, ±3 MHz
Wanted signal at –67 dBm, modulated interferer at ±3
MHz, BER = 10
–3
dB
Selectivity, ±4 MHz
Wanted signal at –67 dBm, modulated interferer at ±4
MHz, BER = 10
–3
dB
Selectivity, ±5 MHz or more
Wanted signal at –67 dBm, modulated interferer at ≥ ±5
MHz, BER = 10
–3
40
dB
Selectivity, image frequency
Wanted signal at –67 dBm, modulated interferer at image
frequency, BER = 10
–3
33
dB
Selectivity, image frequency
±1 MHz
Note that Image fre 1 MHz is the Co- channel
–1 MHz. Wanted signal at –67 dBm, modulated interferer
at ±1 MHz from image frequency, BER = 10
–3
dB
Out-of-band blocking
30 MHz to 2000 MHz
–10
dBm
Out-of-band blocking
2003 MHz to 2399 MHz
–18
dBm
Out-of-band blocking
2484 MHz to 2997 MHz
–12
dBm
Out-of-band blocking
3000 MHz to 12.75 GHz
–2
dBm
Intermodulation
Wanted signal at 2402 MHz, –64 dBm. Two interferers
at 2405 and 2408 MHz respectively, at the given power
level
–42
dBm
Spurious emissions,
30 to 1000 MHz
Measurement in a 50-Ω single-ended load.
< –59
dBm
Spurious emissions,
1 to 12.75 GHz
Measurement in a 50-Ω single-ended load.
< –47
dBm
RSSI dynamic range
70
dB
RSSI accuracy
±4
dB
2 Mbps (LE 2M)
Receiver sensitivity
Differential mode. Measured at SMA connector, BER =
10
–3
–90
dBm
Receiver saturation
Differential mode. Measured at SMA connector, BER =
10
–3
> 5
dBm
Frequency error tolerance
Difference between the incoming carrier frequency and
the internally generated carrier frequency
> (–500 / 500)
kHz
Data rate error tolerance
Difference between incoming data rate and the internally
generated data rate (37-byte packets)
> (–700 / 750)
ppm
SWRS263A – FEBRUARY 2021 – REVISED JUNE 2022
14
Copyright © 2022 Texas Instruments Incorporated
Product Folder Links: