8.14.3.5 32 kHz RC Oscillator (RCOSC_LF)
Measured on a
c
= 25 °C, V
DDS
= 3.0 V, unless otherwise noted.
MIN
TYP
MAX
UNIT
Calibrated frequency
32.8
kHz
Temperature coefficient.
50
ppm/°C
(1)
When using RCOSC_LF as source for the low frequency system clock (SCLK_LF), the accuracy of the SCLK_LF-derived Real Time
Clock (RTC) can be improved by measuring RCOSC_LF relative to XOSC_HF and compensating for the RTC tick speed. This
functionality is available through the TI-provided Power driver.
8.14.4 Synchronous Serial Interface (SSI) Characteristics
8.14.4.1 Synchronous Serial Interface (SSI) Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
NO.
PARAMETER
MIN
TYP
MAX
UNIT
S1
t
clk_per
SSIClk cycle time
12
65024
t
clk_high
SSIClk high time
0.5
t
clk_per
t
clk_low
SSIClk low time
0.5
t
clk_per
(1)
Refer to SSI timing diagrams Figure 8-1, Figure 8-2, and Figure 8-3.
(2)
When using the TI-provided Power driver, the SSI system clock is always 48 MHz.
SSIClk
SSIFss
SSITx
SSIRx
MSB
LSB
S2
S3
S1
4 to 16 bits
Figure 8-1. SSI Timing for TI Frame Format (FRF = 01), Single Transfer Timing Measurement
SWRS263A – FEBRUARY 2021 – REVISED JUNE 2022
20
Copyright © 2022 Texas Instruments Incorporated
Product Folder Links: