Scan IF Operation
30-13
Scan IF
Internal Signal Connections to Timer1_A5
The outputs of the analog front end are connected to 3 different
capture/compare registers of Timer1_A5. The output stage of the analog front
end, shown in Figure 30−7. provides two different modes that are selected by
the SIFCS bit and provides the SIFOx signals to Timer1_A5. See the
device-specific data sheet for connection of these signals.
Figure 30−7. TimerA Output Stage of the Analog Front End
TimerA Output Stage
SIF0OUT
SIF1OUT
SIF2OUT
SIF3OUT
SIFS1x
SIFO0
SIFO1
SIFO2
SIFTESTS1(tsm)
SIFEX(tsm)
SIFCS
11
10
01
00
SIFS2x
11
10
01
00
1
0
1
0
0
1
0
Comparator Output
When SIFCS = 1, the SIFEX(tsm) signal and the comparator output can be
selected as inputs to different Timer1_A5 capture/compare registers. This can
be used to measure the time between excitation of a sensor and the last
oscillation that passes through the comparator or to perform a slope A/D
conversion.
When SIFCS =0, the output bits SIFxOUT can be selected as inputs to
Timer1_A5 with the SIFS1x and SIFS2x bits. This can be used to measure the
duty cycle of SIFxOUT.
Содержание MSP430x4xx Family
Страница 1: ...MSP430x4xx Family 2007 Mixed Signal Products User s Guide SLAU056G ...
Страница 2: ......
Страница 6: ...vi ...
Страница 114: ...3 76 RISC 16 Bit CPU ...
Страница 304: ...5 20 FLL Clock Module ...
Страница 340: ...7 8 Supply Voltage Supervisor ...
Страница 348: ...8 8 16 Bit Hardware Multiplier ...
Страница 372: ...9 24 32 Bit Hardware Multiplier ...
Страница 400: ...10 28 DMA Controller ...
Страница 428: ...13 10 Basic Timer1 ...
Страница 466: ...15 24 Timer_A ...
Страница 522: ...17 30 USART Peripheral Interface UART Mode ...
Страница 544: ...18 22 USART Peripheral Interface SPI Mode ...
Страница 672: ...23 12 Comparator_A ...
Страница 692: ...24 20 LCD Controller ...
Страница 746: ...26 28 ADC12 ...