ADV
ANCEINFORMA
TION
TMS320F28377S, TMS320F28376S, TMS320F28375S, TMS320F28374S
SPRS881A – AUGUST 2014 – REVISED JUNE 2015
shows the HIBERNATE mode timing requirements,
shows the switching
characteristics, and
shows the timing diagram for HIBERNATE mode.
Table 5-34. HIBERNATE Mode Timing Requirements
MIN
MAX
UNIT
t
w(HIBWAKE)
Pulse duration, HIBWAKE signal
40
µs
t
w(WAKEXRS)
Pulse duration, XRS wakeup signal
40
µs
Table 5-35. HIBERNATE Mode Switching Characteristics
over recommended operating conditions (unless otherwise noted)
PARAMETER
MIN
MAX
UNIT
t
d(IDLE-XCOS)
Delay time, IDLE instruction executed to XCLKOUT stop
30t
c(SYSCLK)
cycles
Delay time, external wake signal to loRestore function start
t
d(WAKE-HIB)
ms
1.5
•
Wakeup from flash
80
Specifications
Copyright © 2014–2015, Texas Instruments Incorporated
Product Folder Links: