ref: ED01052c, dated: 19/08/2011
17. Fit 5 Amp fuse for battery.
18. Fit 30 Amp isolation fuse.Secure
powerpack cover in place using
No.8 x 1/2” Stainless steel Pozi-
head screws.
19. Put lift in position referring to
Diagram on page 4 and secure
upper level gate (if supplied) in
desired location
20. The upper call station is mounted in the gate post. Run a 7 core cable
from the upper level gate call station to the charger box. Run the 8 core
cable from the lift, the 4 core cable to the gate lock, and the 7 core from
upper level gate call station along the most appropriate route to the
charger box location and connect as per diagram below. Refer to page 8
for schematic cable run (note all cables to be put in conduit or similar)
Charger Box
Gate Post
Call Station
.
NOTES
Charging
indication light
Charger box dimensions
223mm
92mm
206mm
Cable exit point
Isolating Switch
Содержание Melody 1
Страница 1: ...Installation Manual Melody 1 Platform Lift Ref ED01050g Date 03 04 2012 Original instructions...
Страница 18: ...Terry Melody 1 Installation Instructions ED01050g 18...
Страница 20: ...Terry Melody 1 Installation Instructions ED01050g 20...
Страница 22: ...Terry Melody 1 Installation Instructions ED01050g 22...
Страница 26: ...Terry Melody 1 Installation Instructions ED01050g 26...
Страница 27: ...Terry Melody 1 Installation Instructions ED01050g 27 ref ED01063e dated 10 01 2012 MELODY 1 WIRING DIAGRAM...
Страница 28: ...Terry Melody 1 Installation Instructions ED01050g 28...
Страница 34: ...Terry Melody 1 Installation Instructions ED01050g 34...
Страница 36: ...Terry Melody 1 Installation Instructions ED01050g 36...
Страница 37: ...Terry Melody 1 Installation Instructions ED01050g 37 ref ED01076a dated 10 01 2012 BULLETINS NOTES...
Страница 60: ...Terry Melody 1 Installation Instructions ED01050g 60...
Страница 66: ...Terry Melody 1 Installation Instructions ED01050g 66...