SERVICE
Solution Tank Sensor Output
Tank Level
0 BARS - EMPTY
1 BAR - 20%
2 BARS - 40%
3 BARS - 60%
4 BARS - 80%
5 BARS - FULL
0.0 - 0.72 Volts
0.73 - 0.87 Volts
0.88 - 0.98 Volts
0.99 - 1.11 Volts
1.12 - 1.33 Volts
1.34 + Volts
Output Voltage
SLT002
4 . Slowly fill the solution tank with water and compare
the actual voltmeter readings to the chart below .
replace the sensor if the values are not within
specification .
3 . drain the solution tank .
5 . The solution tank level sensor output voltage is also
viewable in Input display mode . See “Input display
mode” in the TrouBLeShooTIng section .