SERVICE
TESTINg SOLuTION TaNk LEVEL SENSOR
connector terminals a and B using a voltmeter as
shown below . The voltmeter should display 10-12
volts .
VDC
WIRE
POS.
TERMINALS
113/BLK-WHT
A
38/GRY
B
37/PUR
C
B-
B +12vdc
Vdc Output
SLT005
A
B
C
A B C
2 . key on . Backprobe solution tank level sensor
connector terminals a and c using a voltmeter as
shown below . The voltmeter should display 1-5 volts
depending on solution tank water level .
VDC
WIRE
POS.
TERMINALS
113/BLK-WHT
A
38/GRY
B
37/PUR
C
B-
B +12vdc
Vdc Output
SLT004
A
B
C
A B C
1 . key on . Backprobe solution tank level sensor
M
17 Service Information 90
17358
(
08
-
20
1
6
)
for SafetY: Before leaving or servicing machine, stop
on level surface, set parking brake, turn off machine and
remove key.