4-52
M17 Service Information 90
17358
(
08
-
20
16)
TROUBLESHOOTING
Solution Control ON - Main Brush (Conventional)
Battery Po
Battery Negative -
CB6
2.5A
M1B
CSC002
Swit
ched B+
From Key S
wit
ch
Ba
tt
er
y (+)
SV-3 Conventional
Water Solenoid
FUSE 2
100A
8/GRY
16/BLU
Bus Bar
18/GRY
19/WHT
2/RED
-TAN
1/RED
M1
7 Scrub Module
Ba
tt
er
y (-)
J4-18 Key Switch
* SV3 (J4-17) H2O Valve Voltages
Range
Low
1-LED
2-LEDs
3-LEDs
1-LED
2-LEDs
3-LEDs
1-LED
2-LEDs
3-LEDs
16%
31%
47%
31%
47%
63%
47%
63%
83%
Med
(Default)
High
Level
PWM%
NOTE: The period for one cycle is 2 seconds.
For example, 50% would be 1 second On and
one second off. 75% would be 1.5 seconds On
and 0.5 seconds Off.
P1-1 (B+)
B(-) P2-1
CAN(-) J1-2
CAN(+) J1-1
J4-17 Main
Water Solenoid
13/BLK
Twisted
Pair
GRN
YEL
Solution
Control - Main
(Conventional)
Enabled
• 1-STEP Scrub ON
• Solution Control ON
• Fwd/Rev Propel
• 1-STEP Scrub OFF
• Solution Control OFF
• Neutral-Ready State
• Recovery Tank Full
• Solution Tank Empty
• Very Low Batt Voltage
• Circuit Fault
Disabled
Operational Matrix:
Содержание M17 Series
Страница 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Страница 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Страница 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Страница 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Страница 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Страница 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...