FAULT CODES
M17 Service Information 90
17358
(
08
-
20
16)
Fault Code
Number
Fault Code
(Displayed in LCD)
Fault Code
(Displayed on Pro-Panel Screen)
Cause(s)
Action(s)
0x0626
ES Pump Srt
Extended Scrub Pump Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0627
ES Pump FET
Extended Scrub Pump FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0701
Ec Flsh Flt
EC-H2O System Flush Needed
1. The ecH2O module needs a manually triggered flush.
1. Press switch on ecH2O module..
0x0702
Ec Press Sw
EC-H2O Pressure Switch Active
1. The system pressure switch is detecting a trip or
unconnected.
1. System pressure too high, check connections.
2. Verify functionality of scrub head switch and parking
brake switch; maybe connectors were accidentally
wired to incorrect switches.
0x0704
Ec CAN
EC-H2O CAN Communication Fault
1. Control boards are not communicating properly.
2. Board lost power (wiring issue)
3. Breaker supplying power to board tripped.
4. Control board may be damaged.
1. Power cycle machine.
2. Check breaker supplying power to board.
3. No communication with a network module.
0x0711
Ec Pump Opn
EC-H2O Pump Open Fault
1. Wiring, connector or control board issue on the ecH2O
pump.
1. Control board is not detecting pump current. Check
connections for voltage and verify pump is operating
or not.
0x0716
Ec Pump Srt
EC-H2O Pump Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wiring for shorted condition.
2. Replace pump.
0x0717
Ec Pump FET
EC-H2O Pump FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0720
Ec Cell Flt
EC-H2O Cell Generic Fault
1. Generic fault with the EC-H2O cell.
1. Check voltage references.
2. Replace Control Board.
0x0727
Ec Cell FET
EC-H2O Cell FET Faults
1. Control board problem.
2. Power/battery issue on startup.
1. FET detection includes motor, actuator, detergent
pump, vacuum and battery watering pump.
2. Replace board.
0x0730
Ec Spgr Flt
EC-H2O Sparger Generic Fault
1. Generic fault with the EC-H2O sparger.
1. Use trouble-shooting tree to diagnosis.
0x0737
Ec Spgr FET
EC-H2O Sparger FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0751
Ec Vlv Opn
EC-H2O Valve Open Fault
1. Wiring, connector or control board issue on the ecH2O
valve.
1. Control board is not detecting pump current. Check
connections for voltage and verify pump is operating
or not.
0x0756
Ec Vlv Srt
EC-H2O Valve Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check valve and wiring.
2. Replace if out of specifications.
0x0757
Ec Vlv FET
EC-H2O Valve FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0790
SolTnkEmpty
Solution Tank Empty
1. Solution Tank Empty.
2. Wiring, connector, or solution tank switch issue.
1. If tank is not empty, check the tank switch and
wiring.
0x0791
RcvTnk Full
Recovery Tank Full
1. Recovery Tank Full.
2. Wiring, connector, or recovery tank switch issue.
1. If tank is not full, check the tank switch and wiring.
0x07A0
Clogged Filter Warning
1. Filter clogged with dust and debris.
1. Engage filter shaker.
2. Clean filter.
0x07A1
Hopper Fire
Hopper on Fire
1. Hopper on fire.
1. Put hopper fire out.
0x07A2
Hopper not in Home position
1. Hopper not completely lowered.
1. Completely lower hopper.
2. Check system for binding.
0x1003
Down Pressure Unattainable
0x2000
Pascal Flt
Touchscreen Error
1. Touchscreen control board problem.
1. Replace Touchscreen board.
Содержание M17 Series
Страница 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Страница 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Страница 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Страница 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Страница 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Страница 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...