M17 Service Information 90
17358
(
08
-
20
16)
4-9
TROUBLESHOOTING
M
17
FAULT CODES
Fault Code
Number
Fault Code
(Displayed in LCD)
Fault Code
(Displayed on Pro-Panel Screen)
Cause(s)
Action(s)
0x0346
SAF Vlv Srt
Solution AutoFill Valve Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0347
SAF Vlv FET
Solution AutoFill Valve FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0351
RAF Vlv Opn
Recovery AutoFill Valve Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0356
RAF Vlv Srt
Recovery AutoFill Valve Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0357
RAF Vlv FET
Recovery AutoFill Valve FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0501
Vac 1 Opn
Pickup Vac 1 Electrical Open Alert
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0504
Vac 1 OC1
Pickup Vac 1 Over Current 1 Fault
1. Current draw higher than expected.
1. Verify vacuum load, damage and/or usage
conditions.
0x0505
Vac 1 OC2
Pickup Vac 1 Over Current 2 Fault
1. Current draw higher than expected.
1. Verify vacuum load, damage and/or usage
conditions.
0x0507
Vac 1 FET
Pickup Vac 1 FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0511
Vac 2 Opn
Pickup Vac 2 Electrical Open Alert
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0514
Vac 2 OC1
Pickup Vac 2 Over Current 1 Fault
1. Current draw higher than expected.
1. Verify vacuum load, damage and/or usage
conditions.
0x0515
Vac 2 OC2
Pickup Vac 2 Over Current 2 Fault
1. Current draw higher than expected.
1. Verify vacuum load, damage and/or usage
conditions.
0x0517
Vac 2 FET
Pickup Vac 2 FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0520
DstVac1 Flt
Dust Vac 1 Underspeed Fault
1. Motor running too slow.
1. Verify vacuum load, damage and/or usage
conditions.
0x0530
DstVac2 Flt
Dust Vac 2 Underspeed Fault
1. Motor running too slow.
1. Verify vacuum load, damage and/or usage
conditions.
0x0601
SdePump Opn
Side Scrub Pump Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0606
SdePump Srt
Side Scrub Pump Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0607
SdePump FET
Side Scrub Pump FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0611
DetPump Opn
Detergent Pump Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0616
DetPump Srt
Detergent Pump Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0617
DetPump FET
Detergent Pump FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0621
ES Pump Opn
Extended Scrub Pump Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
Содержание M17 Series
Страница 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Страница 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Страница 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Страница 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Страница 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...