4-8
TROUBLESHOOTING
M
17
FAULT CODES
M17 Service Information 90
17358
(
08
-
20
16)
Fault Code
Number
Fault Code
(Displayed in LCD)
Fault Code
(Displayed on Pro-Panel Screen)
Cause(s)
Action(s)
0x0250
LSwpAct Flt
Left Sweep Actuator Generic
0x0257
LSwpAct FET
Left Sweep Actuator FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0260
LiftAct Flt
Hopper Lift Actuator Generic
0x0261
LiftAct Opn
Hopper Lift Actuator Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0267
LiftAct FET
Hopper Lift Actuator FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0270
RollAct Flt
Hopper Roll Actuator Generic
0x0271
RollAct Opn
Hopper Roll Actuator Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0277
RollAct FET
Hopper Roll Actuator FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0278
RollAct Stl
Hopper Roll Actuator Stall
1. Over current.
2. Binding issue.
1. Check amp references.
2. Check system for binding.
0x0301
M Water Opn
Main Water Valve Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0306
M Water Srt
Main Water Valve Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0307
M Water FET
Main Water Valve FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0311
Horn Opn
Horn Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0316
Horn Srt
Horn Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0317
Horn FET
Horn FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0321
Alarm Opn
Alarm Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0326
Alarm Srt
Alarm Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0327
Alarm FET
Alarm FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0331
S Scrub Opn
Side Scrub Valve Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0336
S Scrub Srt
Side Scrub Valve Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0337
S Scrub FET
Side Scrub Valve FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0341
SAF Vlv Opn
Solution AutoFill Valve Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
Содержание M17 Series
Страница 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Страница 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Страница 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Страница 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Страница 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Страница 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...