OPERATION
2-9
235 MM166 (5--91)
CIRCUIT BREAKERS
Circuit breakers are resetable circuit protection
devices designed to stop the flow of current in the
event of a circuit overload. Once tripped, circuit
breakers must be manually reset. If the overload
which caused the circuit breaker to trip is still
present in the circuit, the circuit breaker will
continue to stop current flow until the overload is
corrected.
The circuit breakers are located on the instrument
panel bracket under the seat support.
The following chart shows the various circuit
breakers and the electrical components they
protect.
PROTECTIVE
CIRCUIT
DEVICE
RATING
PROTECTED
CB--1
15 A
Controls
CB--2
10 A
Horn
CB--3
10 A
Filter Shaker
CB--4
10 A
Hopper Dump Door
CB--5
7 A
Hopper Dump Door,
Thermo Sentry
t
and
Air Flow Solenoids
CB--6
15 A
Lights
A
B
03491
CIRCUIT BREAKERS
A. Instrument Panel Bracket
B. Circuit Breakers
HOPPER SUPPORT BAR
The hopper support bar is located on the right
side lift arm. It holds the hopper in a raised
position to allow work to be done under the
hopper. Do not rely on the machine hydraulic
system to keep the hopper raised.
WARNING: Raised Hopper May Fall.
Engage Hopper Support Bar.
Содержание 235
Страница 1: ...235 MM166 Operator Manual ...
Страница 6: ...ABOUT THIS MANUAL 235 MM166 5 91 d ...
Страница 14: ...SPECIFICATIONS 235 MM166 5 91 1 2 ...
Страница 18: ...SPECIFICATIONS 235 MM166 5 91 1 6 ...
Страница 20: ...OPERATION 235 MM166 5 91 2 2 ...
Страница 36: ...OPERATION 235 MM166 5 91 2 18 ...
Страница 49: ...MAINTENANCE 3 13 235 MM166 3 94 03460 HYDRAULIC SCHEMATIC ...
Страница 61: ...MAINTENANCE 3 25 235 MM166 3 94 03489 ELECTRICAL SCHEMATIC ...
Страница 62: ...MAINTENANCE 235 MM166 3 94 3 26 03489 ELECTRICAL SCHEMATIC AUXILIARY SIDE BRUSH ...
Страница 78: ...MAINTENANCE 235 MM166 3 94 3 42 ...
Страница 80: ...APPENDIX 235 MM166 5 91 4 2 ...