9
www.templari.com
Chiller
Outside t
emper
atur
e +/-1 [°C]
Water flow tempe/-2 [°C]
3.3 Structure of the system with heat
pump
The system with heat pump includes following components:
•
External unit KITA Templari® contains cooling circuit;
•
Internal unit KITA Templari® contains all the components of
the hydraulic circuit;
•
Control command of the heating pump;
•
Optional hydraulic components, that can be demanded to
the manufacturer: a heating resistance for the condensate
drain, a 3-way valve to the combined management of the
system and domestic hot water, mesh filter, switching relay
for the operation with integration boiler.
The control of machine functions is totally made by command.
3.4 Components
KITA S - S 3phase - S plus - S plus 3phase -
Si Cold - Si plus Cold - Si Cold 3phase - Si
plus Cold 3phase - Mi - Mi 3phase - Mi Cold
- Mi Cold 3phase: circulator Wilo Para 25/8
iPWM
Model
Wilo Para 25/8 iPWM
Voltage - supply frequency
1-230-V 50/60Hz
Energy efficiency index (EEI)
≤0,21
Maximum power
75 W
Maximum current absorption
0,6 A
Maximum head
8,4 m
Minimum pressure input
0,5 m
Producible water temperature
Da -10°C a 95°C
Characteristic curves of the Circulator
Pressure drop in the plate heat exchanger
Water flow in heating [m
3
/h]
[kP
a]
3.5 Components
KITA Mi plus - Mi plus 3phase - Mi plus Cold -
Mi plus Cold 3phase - L33: circulator Wilo
Para 25/9 iPWM
Model
Wilo Para 25/9 iPWM
Voltage - supply frequency
1-230-V 50/60Hz
Energy efficiency index (EEI)
≤0,21
Maximum power
87 W
Maximum current absorption
0,7 A
Maximum head
9,0 m
Minimum pressure input
0,5 m
Producible water temperature
Da -10°C a 95°C
Содержание KITA L33
Страница 1: ...AIR WATER version T H E H E A T P U M P Installation and maintenance manual...
Страница 5: ......
Страница 72: ...72 www templari com...
Страница 73: ...73 www templari com...