7.1 Sizes and components of the indoor
unit
907
1053
550
146
72
164
220
275
86
61
149
C
B
A
D
E
F
228
164
220
275
86
70
61
B
A
D
E
F
A water inlet /
ingresso acqua
connection /
raccordo
:
1"
B water outlet (plant) /
uscita acqua (impianto)
connection /
raccordo
:
1"
C water outlet (DHW) /
uscita acqua (ACS)
connection /
raccordo
:
1"
D gas flow /
passaggio refrigerante (gas)
outer diameter /
diametro esterno:
22mm
E liquid flow /
passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
12mm
F electrical wiring /
passaggio cavi elettrici
WITHOUT DHW
SENZA ACS
WITH DHW
CON ACS
DATE :
DRAWN BY :
DESCRIPTION:
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
Giovanni B.
KITA INTERNAL UNIT
rev.1
(SPLIT)
04/03/2020
907
1053
550
146
72
164
220
275
86
61
149
C
B
A
D
E
F
228
164
220
275
86
70
61
B
A
D
E
F
A water inlet /
ingresso acqua
connection /
raccordo
:
1"
B water outlet (plant) /
uscita acqua (impianto)
connection /
raccordo
:
1"
C water outlet (DHW) /
uscita acqua (ACS)
connection /
raccordo
:
1"
D gas flow /
passaggio refrigerante (gas)
outer diameter /
diametro esterno:
22mm
E liquid flow /
passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
12mm
F electrical wiring /
passaggio cavi elettrici
WITHOUT DHW
SENZA ACS
WITH DHW
CON ACS
DATE :
DRAWN BY :
DESCRIPTION:
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
Giovanni B.
KITA INTERNAL UNIT
rev.1
(SPLIT)
04/03/2020
Threaded water connections 1”M
WIth DHW
907
1053
550
146
72
164
220
275
86
61
149
C
B
A
D
E
F
228
164
220
275
86
70
61
B
A
D
E
F
A water inlet /
ingresso acqua
connection /
raccordo
:
1"
B water outlet (plant) /
uscita acqua (impianto)
connection /
raccordo
:
1"
C water outlet (DHW) /
uscita acqua (ACS)
connection /
raccordo
:
1"
D gas flow /
passaggio refrigerante (gas)
outer diameter /
diametro esterno:
22mm
E liquid flow /
passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
12mm
F electrical wiring /
passaggio cavi elettrici
WITHOUT DHW
SENZA ACS
WITH DHW
CON ACS
DATE :
DRAWN BY :
DESCRIPTION:
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
Giovanni B.
KITA INTERNAL UNIT
rev.1
(SPLIT)
04/03/2020
WIthout DHW
907
1053
550
146
72
164
220
275
86
61
149
C
B
A
D
E
F
228
164
220
275
86
70
61
B
A
D
E
F
A water inlet /
ingresso acqua
connection /
raccordo
:
1"
B water outlet (plant) /
uscita acqua (impianto)
connection /
raccordo
:
1"
C water outlet (DHW) /
uscita acqua (ACS)
connection /
raccordo
:
1"
D gas flow /
passaggio refrigerante (gas)
outer diameter /
diametro esterno:
22mm
E liquid flow /
passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
12mm
F electrical wiring /
passaggio cavi elettrici
WITHOUT DHW
SENZA ACS
WITH DHW
CON ACS
DATE :
DRAWN BY :
DESCRIPTION:
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
Giovanni B.
KITA INTERNAL UNIT
rev.1
(SPLIT)
04/03/2020
A: water inlet - connection Ø 1”
B: water outlet (plant) - connection 1”
C: water outlet (DHW) - connection 1”
D: gas flow - outer diameter: has shown in data table page 23
E: liquid flow - outer diameter 12mm
F: electrical wiring
Mounting wall bracket
76,34
500
5,34
16,01
35
165
65
40
6,09
9
340
7
62
14
7
50
215
215
35
35
10
500
9
14
7.2 General information and choice of
the place to instal the indoor unit
WARNINGS!
It is suitable to instal a security valve on the hydraulic system.
The assembly of the security valve has to be made by a qualified
staff
•
Instal the hydronic unit indoor.
•
The hydronic unit can’t be installed near heating or steam
sources. Besides it is suitable not to instal the unit in humid
environments.
•
Instal the indoor unit respecting the minimum distances
from walls and obstacle to facilitate mounting and
maintenance operation.
•
Grant a correct air flow.
•
Instal the hydronic unit in a vertical position, as shown in
figure paragraphe 7.1.
7.3 Assembly of the indoor unit
The hydronic unit has to be fixed on the wall by anchors and L
supports, getting a grip on the back bracket of the carpentry.
On the bottom of the carpentry there is another support for a
definitive and sure anchorage.
•
the drilling for the support has to respect the mentioned
sizes.
•
Lift the unit and hang it on the wall. More than a person is
needed, since the heavy weight can cause injuries.