19
www.templari.com
KITA Li Plus
CON STAFFE
A: gas flow - outer diameter: 28 mm
B: refrigerant liquid flow - outer diameter: 16
C: condensate drain - outer diameter 40 mm
D: electrical wiring
6.3 Free spaces to assembly the outdoor
unit
Distance
Sizes in millimeters
A
>300
B
>2500
C
>300 KITA S >400 KITA M >500 KITA L
D
>3000
E
>1000
Respect the minimum distance mentioned above to ensure a
sufficient air flow and to facilitate maintenace works.
•
Verify there is space enough to instal hydraulic pipes.
•
If the product is installed in areas subject to heavy
knowfalls, verify the snow isn’t accumulated around the
product and the minimum distances mentioned above are
respected. If these conditions can’t be satisfied, instal then
an additional heat generator in the heating circuit.
6.4 Choice of the installation place
•
Respect all the current rules.
•
Instal the product outside the building.
•
Don’t instal the product:
- near a heat source,
- near flammable substances,
- near the fan opening of next buildings,
- under deciduous trees.
•
To instal the product observe:
- prevailing winds,
- acoustic emissions of the fan and the compressor,
- optical impression on the environment.
•
Avoid places having the effect of strong winds on the air
output of the product.
•
Don’t position the fan in the direction of near windows.
•
If necessary, instal noise-protection systems.
•
Instal the product on one of the following supports
- Concrete pavement,
- T beam steel
- Concrete block.
•
Don’t expose the product to dusty and corrosive air (for
example near rough roads).
•
Don’t instal the product near air leaking wells.
DATE :
DRAWN BY :
DESCRIPTION:
Giovanni B.
06/03/2020
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
KITA L Plus
SPLIT VERSION
80
53
117
117
55
155
302
1423
240
93
93
770 956
1148
6.5 X 88
2027
D
C
1413
40
2027
1373
115
40
72
91
CONNECTIONS DETAIL
DETTAGLIO CONNESSIONI
A gas flow / passaggio refrigerante (gas)
outer diameter /
diametro esterno:
28mm
B liquid flow / passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
16mm
C condensate drain /
scarico condensa
outer diameter /
diametro esterno:
40mm
D electrical wiring /
passaggio cavi ele�rici
D
A
B
DATE :
DRAWN BY :
DESCRIPTION:
Giovanni B.
06/03/2020
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
KITA L Plus
SPLIT VERSION
80
53
117
117
55
155
302
1423
240
93
93
770 956
1148
6.5 X 88
2027
D
C
1413
40
2027
1373
115
40
72
91
CONNECTIONS DETAIL
DETTAGLIO CONNESSIONI
A gas flow / passaggio refrigerante (gas)
outer diameter /
diametro esterno:
28mm
B liquid flow / passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
16mm
C condensate drain /
scarico condensa
outer diameter /
diametro esterno:
40mm
D electrical wiring /
passaggio cavi ele�rici
D
A
B
Содержание KITA L33
Страница 1: ...AIR WATER version T H E H E A T P U M P Installation and maintenance manual...
Страница 5: ......
Страница 72: ...72 www templari com...
Страница 73: ...73 www templari com...