![Templari KITA L33 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/templari/kita-l33/kita-l33_installation-and-maintenance-manual_1085668008.webp)
8
www.templari.com
•
Heating: minimum temperature 10°C, maximum
temperature 55°C
•
Domestic hot water production: minimum temperature
35°C, maximum temperature 55°C
•
Cooling: minimum temperature 7°C, maximum
temperature 40°C.
The Kita Templari heat pump is equipped with a safety pressure
switch, which interrupts the operation of the machine when a
pressure of 4.5 MPa (45 bar) is reached.
The product is equipped with a volume flow sensor (flow meter).
The flowmeter ensures that the machine stops when the water
flow rate falls below the minimum threshold of 35-40% of the
rated flow.
The following table shows the minimum flow and the resulting
error threshold for each heat pump model:
Model
flow meter
l/h
l/m
S/ S 3Phase
DN20
1512
25,2
S Plus/ S Plus 3Phase
DN20
1512
25,2
Si / Si 3Phase
DN20
1512
25,2
Si Cold /Si Cold 3Phase DN20
1512
25,2
Si Plus / Si Plus Cold
3Phase
DN20
1512
25,2
Si Plus Cold / Si Plus
Cold 3Phase
DN20
1512
25,2
Mi / Mi 3Phase
DN20
1698
28,3
Mi Cold / Mi Cold
3Phase
DN20
1698
28,3
Mi Plus / Mi Plus
3Phase
DN20
1698
28,3
Mi Plus Cold / Mi Plus
Cold 3Phase
DN20
1698
28,3
L33
DN20
1698
28,3
L42
DN25
2520
42
L66
DN25
2520
42
L Cold
DN25
2520
42
Li Plus
DN32
3000
50
WARNINGS!
Before any maintenance works on the machine make sure to
disconnect the machine from power supply.
•
During summer operation a frost protection prevent water
freezing of the system.
•
The heat pump
KITA Templari® is equipped with an only
probe controling the drain temperature of the compressor.
The computer of the machine grants the drain temperature
is more than the maximum acceptable.
NOTE!
It isn’t suitable to use the machine with a frequency converter.
If the machine is unplagged for long periods, don’t stop the
process of oil heating starting when the machine is turned on
again. This process needs to avoid that the compressor breaks.
3.2 Allowed operative zone
3.2.1 KITA with Twin Rotary
KITA S - S 3phase - S plus - S plus 3phase:
Heat pump
W
at
er flo
w t
emper
atur
e +/-2 [°C]
Outside tempe/-1 [°C]
Chiller
Outside t
emper
atur
e +/-1 [°C]
Water flow tempe/-2 [°C]
3.2.2. KITA with scroll vapour injection
KITA Si - Si 3Phase - Si Cold - Si Cold 3Phase
- Si Plus - Si Plus 3Phase - Si Plus Cold - Si
Plus Cold 3Phase - Mi - Mi 3Phase - Mi
Cold - Mi Cold 3Phase - Mi Plus - Mi Plus
3Phase - Mi Plus Cold - Mi Plus Cold
3Phase - L33 - L42 - L66 - L66 Cold - Li Plus:
Heat pump
W
at
er flo
w t
emper
atur
e +/-2 [°C]
Outside tempe/-1 [°C]
Содержание KITA L33