20
www.templari.com
Frost proof
depth
min 250mm
Frost
proof
depth
•
Basement preparation of condensate drain
•
Example 1 condensate drain (it is suitable to inter the
condensate drain tube to avoid if you don’t buy the heating
resistance for condensate drain as optional).
Frost proof
depth
min 250mm
Frost
proof
depth
•
Prepare cable laying.
•
In places where there are snowfalls, instal the heat pump
25 cm from the floor at least to avoid obstruction of the
suction zone and the condensate drain.
6.5 Outdoor unit assembly
1. Before installing the product, respect the safety warnings
contained in this manual and in service manuals.
2. Assembly the product on steel beams, concrete blocks or
helped by a wall support (optional).
3. Verify that water isn’t accumulate under the product.
4. Verify that the pavement in front of the product can well
absorb the water to avoid ice formation.
6.6 Preparation of condensate drain
The condensate is drained in a centralized way from the back of
the heat pump
KITA Templari®.
Prepare the condensate drain by drain pipe or gravel bed.
WARNINGS!
The frozen condensate on the avenues can cause falls. Verify the
condensate isn’t drained on the avenues being able to freez on
these.
Frost proof
depth
min 250mm
Frost
proof
depth
Frost proof
depth
min 250mm
Frost
proof
depth