11
www.templari.com
3.8 Operation mode
The heat pump can work according two modes, actionable
through the commutation of 4-way valve: as explained below,
these modes are heating and cooling/defrosting.
It’s also possible to insert a suitable management mode DHW
(domestic hot water) composed by relays, temperature sensors
and 3-way valve. For this reason the pump can manage the
domestic as a priority both in summer than in winter.
Heating mode
1
Evaporator
2
4-way valve
3
Fan
4
Compressor
5
Electronic expansion
valve
6
Plate heat exchanger
Heating and cooling mode
1
Evaporator
2
4-way valve
3
Ventilator
4
Compressor
5
Electronic expansion
valve
6
Plate heat exchanger
4 Scope of supply
4.1 Main unit
The heat pump
KITA Templari® is supplied in 2 unità and it is
composed by the components shown in figur 1.
4.2 Type name and serial number
Model name and serial number are on the plate (1) figure 1.
1
Templari srl
Via Pitagora 20/A 35030 Rubano - PD
[email protected] +39 049 5225929
Wärmepumpe / Heat pump/Chiller / Pompa di calore
Model / Model / Modello
KITA M SPLIT
Baujahr / time of production / Anno di fabbricazione 2020
Wärmeleistung / Heating Capacity / Potenza nominale
a pieno regime in riscaldamento
16,58 kW
Kühlleistung / Cooling Capacity / Potenza nominale
a pieno regime in raffreddamento
13,50 kW
Anschluss-Spannung / Supply / Alimentazione
230V / 50Hz
Maximaler Laststrom / Maximum Input Current /
Massima corrente assorbita
29A cosØ 0,9
Gewicht / Weight / Peso netto OUTDOOR - INDOOR 200 / 50 kg
DGRL Kategorie / PED Category / Categoria PED
I
R410a Kältemittelmenge / Refrigerant Charge R410A /
Refrigerante R410a
6,5 kg
CO2-Äquivalent / CO2 equivalents / CO2 equivalente 13.572 Kg
Maximal zulässigen Druck / Max pressure permissible /
Pressione massima ammissibile
Hp: 45 bar
Lp: 30 bar
Kompressortyp / Compressor type / Tipo compressore Inj
Hinweis: die Wärmeleistung wurde in Standardkonditionen geprüft, mit
trockene/nasse Testspitze 7 (6)°C, Wassertemperatur
in/out 30/35°C. Die Kühlleistung wurde in Standardkonditionen geprüft, mit
trockene Testspitze 35°C, Wassertemperatur
in/out 18/23°C. Leistungswerte nach den Norm EN14511.
Nota: Heating capacity tested in standard condition of temperature: external 7/6°C
dry/wet bulb and 30/35°C water inlet/outlet temperature Cooling capacity tested in
standard condition of temperature: external 35°C dry bulb and 18/23°C inlet/outlet
water temperature Tests in accompliace with EN14511.
Nota: La capacità di riscaldamento è stata testata in un ambiente standard con
temperatura di test di bulbo secco/bagnato 7 (6)°C temperatura dell’acqua in/out
30/35°C. La capacità di raffrescamento è stata testata in un ambiente standard con
temperatura di test di bulbo secco 35°C temperatura dell’acqua in/out 18/23°C.
Valori di potenza resa in accordo con norma EN14511.
S.N. K001713
figure 1
Содержание KITA L33
Страница 1: ...AIR WATER version T H E H E A T P U M P Installation and maintenance manual...
Страница 5: ......
Страница 72: ...72 www templari com...
Страница 73: ...73 www templari com...