2 Read carefully before use
2.1 Important information
WARNINGS!
The exercise and the maintenance of the heating pump
KITA
Templari®, are subjects to the legal system of the countries
where it is used. According to the quantity of the cooling fluid it
is necessary to regularly check and note the sealing of the heat
pump resorting to a qualified staff.
•
During the transport it is possible to tilt the heating pump
no more than 45° (in every direction).
•
The security for the transport has to be removed before
the startup.
•
The aspiration and drain zone can’t be reduced or covered.
•
Respect the specific building regulation of the individual
countries.
•
Concerning the installation near the wall you have to
consider the influences caused by factors in building
physiscs. In the drain area of the fan there can’t be windows
or doors.
•
With the installation near the wall the air flow in the
aspiration and drain zone can increase deposits of
impurities. The colder outside air has to exit so not to
increase the heat loss of the heated rooms nearby.
•
The dirt trap, not supplied but available on customer’s
demand, has to be assembly on the return pipes upstream
of the heat pump.
•
The installation in niches and courtyards isn’t allowed,
since the cold air accumulates on the ground and in case of
prolonged operation it would be sucked back by the heat
pump.
•
The freezing limit can change according to the climatic region.
Respect the current rules for the countries concerned.
•
Respect the right-handed rotation camp: in case of wrong
wiring the startup of the heat pump is thwarted. Heat pump
programmer shows the relevant warnings (correct the wiring).
•
The operation of the heat pump with too low system
temperatures can cause its total stop. After prolonged power
cut use the startup method described below.
•
Regularly clean the dirt trap.
•
Prior to opeing the unit cut off power to all electrical circuits.
• The intervention on the heat pump can just be made by service
authorized and competent staff.
2.2 Proper use
The heat pump
KITA Templari® is approved just for the intended
use by the manufacturer. A different use leaving the proper
one is considered non-compliant. Proper use comprende also
includes the respect of the instructions contained in the relevant
information material. It is forbidden to make unit changes or
transformation.
2.3 Rules and legal provisions
This heat pump is intended, according the art. 1, chapter 2 k)
of the EC directive 2006/42/CE (Machines Directive), to the
domestic use and for this reason it is subject to the requirements
of the Directive 2006/95/CE (Low voltage Directive). In this way
it is intended to be used by inexperienced to heat shps, offices
and more similar workplaces, in farms, hotels, guest-houses and
similar or other housing structures.
In the design and realization of the heat pump all the EC directive
and DIN and VDE rules (see Declaration of conformity EC) have
been respected.
The electrical connection of the heat pump
KITA Templari®
has to be made according to VDE, EN and CEI current rules.
Furthermore supply networks managers connection conditions
have to be respected.
Concerning the connection of the heating system attenersi
respect the current dispositions concerned.
People, in particular children, basing on their physical, sensory or
mental ability, or because they are inexperienced or incompetent
can’t safely use the machine, mustn’t use the machine without a
responsible person’s supervision and guide.
Make sure children not to play with the machine.
2.4 Energy saving
Using the heat pump
KITA Templari® you contribute to the
environmental protection. Saving energy mode is based on the
correct arrangement of the system and the heat sources to use
thermal energy.
Really important for the efficiency of a heat pump is to keep the
difference of temperature between heating water and heat source
as low as possible. For this reason it is strongly recommended
an accurate sizing of the heat source and the heating system. A
difference of temperature a degree Kelvin higher (one °C) causes
an increaing of 2,5% about energy consumption. It is necessary
to be careful, during the sizing of the heating system, to special
users treatment, as for example the production of hot water, and
their sizing to low temperature. The floor heating is perfect to
use a heat pump thanks to low flow temperature (from 30 °C to
40 °C).
During the operation impurities aren’t accumulated in heat
exchangers, since they increase the difference of temperature,
worsening the coefficient of performance.
3 Intended use of the heat
pump
3.1 Field of work and safety devices
The heat pump
KITA Templari® is enhabled to work outside
temperatures included between -22°C (for version S and M) and
-32°C (for version L) and +46°C.
The machine allows following operation fields according to the
temperatures of produced water:
Содержание KITA L33