Appendix C
CV - Shut Off Voltage
Purpose:
Sets the shutoff voltage level.
Format: CV
nnn
Range:
nnn
= 0 to 999 volts.
Default: CV012
Description: The shutoff voltage determines at what voltage the ADFM
will stop pinging during the deployment cycle. If the system
detects a low voltage condition for five consecutive ensem-
bles, the ADFM will shutdown. The recommended shutoff
voltage level for alkaline batteries is 12 volts and 20 volts for
lead acid batteries.
CZ - Power Down ADFM
Purpose:
Tells the ADFM to power down.
Format: CZ
Description: An ESC interrupts ADFM processing and returns it to the
STANDBY mode. An ESC does not remove the settings
stored in battery-backed RAM.
Example: >CZ
[POWERING DOWN]
page C-12