Appendix C
QF - Force Depth
Purpose:
Force the depth of the channel or pipe to a set value.
Format: QF
nnnnn
Range:
nnnnn
= 1 to 10000 mm (0 = off)
Default: QF00000
Description: Force the depth of the channel or pipe to a set value.
QH - Pipe Heights/Epsilons
Purpose:
Sets the height/epsilons value of the pipe or channel.
Format: QH
nnnn
,
nnnn
,
nnnn
Range:
nnnn
= 0 to 9999
Default: QH0000,0050,0100
Description: Use this command to describe the height/epsilon values of the
pipe or channel.
a3
a2
a1
R1
R2
R2
R3
Circular or Egged-shaped:
R = Radii in meters
a = Angles in degrees
W3
W2
W1
H3
H2
H1
Rectangular and Trapezoidal shaped:
H = Heights in meters
W = Widths in meters
y
z
x
Figure C-1.
Pipe Heights/Epsilons
QO - Transducer Offset from Pipe Bottom
Purpose:
Sets the transducer offset from the pipe or channel bottom.
Format: QO+
nnnn
Range:
nnnn
= -50 to 2000 mm
Default: QO+0000
Description: If the transducer is not resting on the bottom of the pipe or
channel and water flow
is
possible under the transducer, use
this command to set the depth of the transducer from the bot-
tom of the pipe or channel to the top of the transducer face.
page C-34
MGD Technologies, Inc.
Содержание ADFM Analog Output Module
Страница 2: ......
Страница 6: ...Table of Contents NOTES iv MGD Technologies Inc ...
Страница 13: ...Table of Contents NOTES ADFM Technical Manual January 2000 xi ...
Страница 14: ...Table of Contents xii MGD Technologies Inc ...
Страница 54: ...Chapter 5 NOTES page 5 10 MGD Technologies Inc ...
Страница 132: ...Appendix C NOTES page C 52 MGD Technologies Inc ...
Страница 152: ...Appendix E NOTES page E 14 MGD Technologies Inc ...
Страница 154: ......
Страница 155: ......
Страница 156: ......