ADFM Test Procedures
5-4.5 Modem
Test
This test checks the modem operation.
a. Start
BBTALK
. Press the
End
key to wake the ADFM.
b. Type
CP
to clear the fault log.
c. Type
MP1
to turn the modem power on.
d. Type
MO
.
e. Verify these readings are present and correct.
>mp1
>mo
Modem is OK
Modem state/connect status = COMMAND/NOT CONNECTED
Primary Port = RS-232
f. Type
MP0
to turn the modem power off.
g. Type
MO
.
h. Verify these readings are present and correct.
>mp0
>mo
Modem is NOT OK
Modem state/connect status = OFF/NOT CONNECTED
Primary Port = RS-232
>
5-4.6 Recorder
Test
This tests the recorder — it does not destroy any data.
a. Start
BBTALK
. Press the
End
key to wake the ADFM.
b. Type
CP
to clear the fault log.
c. Type
RT
.
d. Verify these readings are present and correct for your system.
>rt
Recorder Message... 0 1 14 0 0
RAM --------------PASS
Cards Found ------ 1
Memory Found ----- 20 MB
Write/Read -------PASS
Block Copy -------PASS
Recorder NOT Erased
Recorder BIT...PASS
>
ADFM Technical Manual (January 2000)
page 5-7
Содержание ADFM Analog Output Module
Страница 2: ......
Страница 6: ...Table of Contents NOTES iv MGD Technologies Inc ...
Страница 13: ...Table of Contents NOTES ADFM Technical Manual January 2000 xi ...
Страница 14: ...Table of Contents xii MGD Technologies Inc ...
Страница 54: ...Chapter 5 NOTES page 5 10 MGD Technologies Inc ...
Страница 132: ...Appendix C NOTES page C 52 MGD Technologies Inc ...
Страница 152: ...Appendix E NOTES page E 14 MGD Technologies Inc ...
Страница 154: ......
Страница 155: ......
Страница 156: ......