![Teledyne SP Devices ADQ3 Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/teledyne-sp-devices/adq3-series/adq3-series_user-manual_1081093011.webp)
Classification
Revision
Public
B
Document ID
Print date
20-2507
2022-03-31
Figure 1: The HTML report from
devkit_analyze
rendered in a web browser.
and values without an upper boundary are formatted as
Value (Difference)
The difference is calculated by subtracting the value from the previous report from the current value.
Each parameter also has a trend graph that provides a quick overview of the result. Fig.
shows a
section from the report. A value displayed in red indicates an error that
must
be addressed. Warnings
that
may
require investigation are shown in orange.
Figure 2: Excerpt of the utilization section from the
devkit_analyze
report.
The report contains the following sections:
Critical warnings
These warnings must be fixed, or at least, well understood.
CDC Critical
Check the
reports/post_impl.rpt
for details.
Synth Critical
Check the
reports/synth_runme.log
for details.