background image

Installation Guide

TSBC3000 Session Border Controller

August 31, 2016

Содержание TSBC3000

Страница 1: ...Installation Guide TSBC3000 Session Border Controller August 31 2016...

Страница 2: ...tinually improving product designs as a result product specifications may be subject to change without notification 2003 2016 TelcoBridges All rights reserved TelcoBridges Tmedia TMG800 TMG3200 TMG320...

Страница 3: ...description applies to the TSBC3000 session border controller operating in conjunction with the TSBC3000 1 series unit This term may include the 1 1 patch panel when using TDM fall back capability TS...

Страница 4: ...ting and follow those procedures throughout this guide to ensure proper equipment installation and set up Graphics Description This icon appears in the margins of pages describing the TSBC3000 series...

Страница 5: ...2 4 2 Connecting to a VoIP Network 15 2 4 3 Connecting to the PSTN Optional TDM fall back feature 16 2 4 4 Grounding the Equipment Chassis 17 2 4 5 Powering Up 18 2 4 5 1 Connecting to AC Power 18 2...

Страница 6: ...SBC3000 Series Serial Connection 46 3 2 1 Physical Connection 46 3 2 1 1 Connecting to the USB Port of the TSBC3000 Series 47 3 2 1 2 Connecting to the Serial Port of the TSBC3000 Series 47 3 2 2 Conf...

Страница 7: ...lone mode TSBC3000 series 1 1 system TSBC3000 series unit operating in conjunction with a with a TSBC3000 series 1 unit and an optional 1 1 patch panel s The following topics are covered Section 1 1 R...

Страница 8: ...1 1 system see figure 1 1 on page 2 consists of One TSBC3000 session border controller One TSBC3000 1 session border controller One or two 1 1 patch panels Optional TDM fall back feature Figure 1 1 E...

Страница 9: ...ower source IP addresses for the management ports To avoid delays you should have the IP address netmask and session border controller addresses on hand Take note that the management port supports DHC...

Страница 10: ...hocks the wrist strap and cord must be in proper working condition If no wrist strap is available and you must work with the equipment ground yourself by touching a metal part of the chassis 1 4 Recom...

Страница 11: ...BC3000 Series Standalone or the TSBC3000 Series 1 1 System Section 2 3 Choosing your Connection Procedures Section 2 4 TSBC3000 Series Standalone Section 2 5 TSBC3000 Series 1 1 System Section 2 6 Add...

Страница 12: ...ne set of mounting brackets and screws used to mount the TSBC3000 series unit to a 19 rack One Tsbc serial adapter to interface the serial port of your computer with the RJ 45 port of the TSBC3000 ser...

Страница 13: ...its Two AC power cables Not included A 19 equipment rack The TSBC3000 series unit must be installed in a standard 19 wide equipment rack TSBC3000 680 1 TSBC3000 2700 1 One TSB3000 1 series unit See fi...

Страница 14: ...r connection of each grouping of 8 lines of the TSBC3000 series 1 1 system Cables provided You are provided with 16 RJ48C cables yellow two meters in length with your 1 1 Patch Panel 8 T1 E1 Table 2 1...

Страница 15: ...ch housed in a 1U chassis as tabulated in table 2 2 on page 9 It is important that you provide for enough room on the equipment rack to allow for the installation of the equipment Consider the availab...

Страница 16: ...in figure 2 1 on page 11 Do the same for the angle bracket on the right hand side 2 Start mounting equipment at the top most position of the rack keeping in mind the space required on the equipment r...

Страница 17: ...0 Series Standalone TSBC3000 Series 1 1 System Network Gateway Gateway 1 1 Patch Panel 8 T1 E1 1 1 Patch Panel only used by 3000 680 with fall back TSBC TDM Network Gateway Gateway 1 1 Patch Panel 8 T...

Страница 18: ...oosing Your Setup TSBC3000 Series Standalone I am setting up a TSBC3000 series as a standalone unit I am setting up a TSBC3000 series 1 1 system including a TSBC3000 series unit and a TSBC3000 series...

Страница 19: ...andalone system This section covers the following procedures Section 2 4 1 Connecting to the TSBC3000 Series Management Interface Section 2 4 2 Connecting to a VoIP Network Section 2 4 3 Connecting to...

Страница 20: ...ect the other end of the same CAT5 cable to the first gigabit Ethernet switch 2 In the case of a TSBC3000 680 if your system employs a second gigabit Ethernet switch for redundancy connect a second CA...

Страница 21: ...male terminations Connections The TSBC3000 series is connected to the VoIP network by one or optionally two Ethernet GigE network links as shown in figure 2 3 on page 15 To connect the TSBC3000 serie...

Страница 22: ...vert the line impedance to 75 ohms If you are making your own cables refer to Section A 1 RJ48C T1 E1 Wiring Diagram Crossover and Straight Cables on page 53 for crossover or straight cable wiring con...

Страница 23: ...h of the ground wire as short as possible Do NOT daisy chain the ground between equipment Use a ground bus bar as show in figure 2 5 on page 17 Do not over tighten ground lug connections To connect th...

Страница 24: ...er Prerequisites To power the TSBC3000 series you will need Two power sources Two power cables for the TSBC3000 series To connect to AC Power 1 Connect an AC power cable to each AC connector of the TS...

Страница 25: ...own in figure 2 7 on page 19 2 Connect another wire from the negative terminal of the TSBC3000 series to the 48V side of DC power source one 3 Connect a ground wire from the ground terminal of the TSB...

Страница 26: ...our TSBC3000 series starts up and displays the web portal configuration management tool Note To learn about the IP address for your system or how to change it refer to Section 3 5 Changing the TSBC300...

Страница 27: ...the TSBC3000 Series 1 1 System Management Interfaces Section 2 5 2 Connecting to the TSBC3000 Series 1 1 System Control Network Section 2 5 3 Connecting to the TSBC3000 Series 1 1 System VoIP Network...

Страница 28: ...oller each using a gigabit Ethernet network link See figure 2 8 on page 23 TSBC3000 680 To communicate with the management interface 1 Connect a CAT5 Ethernet cable to the port labeled MGMT0 at the re...

Страница 29: ...ment Port IP Address on page 49 Management Interface 2 TSBC3000 680 TSBC3000 680 1 15 14 13 12 10 11 8 9 3 2 0 7 6 5 4 1 MGMT0 MGMT1 ETH0 ETH1 VOIP0 VOIP1 15 14 13 12 10 11 8 9 3 2 0 7 6 5 4 1 MGMT0 M...

Страница 30: ...male male terminations To connect to the control network 1 Connect one CAT5 Ethernet cable between ports ETH0 of both the TSBC3000 series and TSBC3000 series 1 units 2 Connect a second CAT5 Ethernet c...

Страница 31: ...BC3000 series 1 1 system requires two 2 gigabit layer 2 Ethernet switches Prerequisites To connect to the VoIP network you will need Two gigabit layer 2 Ethernet switches A second one is required to s...

Страница 32: ...P Network 1 15 14 13 12 10 11 8 9 3 2 0 7 6 5 4 1 MGMT0 MGMT1 ETH0 ETH1 VOIP0 VOIP1 15 14 13 12 10 11 8 9 3 2 0 7 6 5 4 1 MGMT0 MGMT1 ETH0 ETH1 VOIP0 VOIP1 VoIP Network 1 VoIP Network 2 TSBC3000 680 T...

Страница 33: ...are activated by software license the number of active ports depends on the licenses purchased Patch panels use straight connections In other words they do not cross the RX and TX signals Connections...

Страница 34: ...T1 E1 Network Gateway Gateway 1 1 Patch Panel 8 T1 E1 TSBC3000 680 TSBC3000 680 1 TSBC3000 680 TSBC3000 680 1 From Network 15 14 13 12 10 11 8 9 3 2 0 7 6 5 4 1 MGMT0 MGMT1 ETH0 ETH1 VOIP0 VOIP1 15 1...

Страница 35: ...ide of ground wire with a 10 ring terminal Keep the length of the ground wire as short as possible Do NOT daisy chain the ground between equipment Use a ground bus bar as show in figure 2 12 on page 2...

Страница 36: ...Two power sources Two power cables for every TSBC3000 series and TSBC3000 series 1 unit 2 5 6 1 Connecting to AC Power To connect to AC Power 1 Connect the first power connector of each unit to the fi...

Страница 37: ...he 48V side of DC power source one 3 Connect a ground wire from the ground terminal of the TSBC3000 series to earth ground 4 Repeat steps 1 3 for the second power DC power source Figure 2 14 TSBC3000...

Страница 38: ...and display the web portal configuration management tool Note To learn about the IP address for your system or how to change it refer to Section 3 5 Changing the TSBC3000 Series Management Port IP Add...

Страница 39: ...ing the Equipment Note Default values are fine for most deployments Adjust values only when necessary Repeat steps one and two for the secondary unit 3 Once you confirm the changes a progress page is...

Страница 40: ...eries 1 1 System Section 2 6 2 Install the TSBC3000 Series 1 unit on the Equipment Rack Section 2 6 3 Install the 1 1 Patch Panel Section 2 6 4 Connect to the TSBC3000 Series 1 1 Management Interface...

Страница 41: ...35 Installing the Equipment 3 Select a host from the Host Configuration List 4 Select the Status tab...

Страница 42: ...es Standalone and TSBC3000 Series 1 1 System Installation Guide 36 5 Select Reset Host Role 6 Follow the instructions of the web portal to configure your unit as a primary unit in a new TSBC3000 serie...

Страница 43: ...t interface to different Ethernet switches If you are installing a TSBC3000 series 1 unit the associated one or two 1 1 patch panels will look like the image to the right Refer to Section 2 2 3 Instal...

Страница 44: ...ntinue to manage VoIP traffic using the alternate network Follow the procedure described in Section 2 5 2 Connecting to the TSBC3000 Series 1 1 System Control Network on page 24 15 14 13 12 10 11 8 9...

Страница 45: ...s must be properly grounded to protect against any contact with an electrical fault condition Refer to Section 2 5 5 Grounding the Equipment Chassis on page 29 2 6 9 Power Up the Equipment The TSBC300...

Страница 46: ...learn about the IP address for your system or how to change it refer to Section 3 5 Changing the TSBC3000 Series Management Port IP Address on page 49 1 Connect to the web portal of the TSBC3000 serie...

Страница 47: ...2 3 on page 41 Table 2 3 TSBC3000 Series Unit Displays Note An alarm will sound if one of the power supplies is faulty There is no alarm button to disable the alarm To stop the alarm you must remove...

Страница 48: ...tton or the web portal 2 8 1 Management Port To shut down the unit using the management port connect to the management interface using SSH and enter shutdown hP now 2 8 2 Power Button To shut down the...

Страница 49: ...43 Installing the Equipment 2 Click the Status tab 3 Select the host that you wish to shut down 4 Select Shutdown from the Action Log...

Страница 50: ...TSBC3000 Series Standalone and TSBC3000 Series 1 1 System Installation Guide 44...

Страница 51: ...Section 3 3 Changing TSBC3000 Series Management Port Passwords Section 3 4 Retrieving TSBC3000 Series Information Section 3 5 Changing the TSBC3000 Series Management Port IP Address Section 3 3 Chang...

Страница 52: ...word is set at the factory and is indicated on the shipment sheet Figure 3 1 TSBC300 Series Session Border Controller Management Interface Note See Section 3 5 on page 49 to learn how to change the IP...

Страница 53: ...to the Serial Port of the TSBC3000 Series Note The default IP addresses for the management ports are located in the Important Notice sheet received with the shipment For the TSBC3000 680 MGMT ports a...

Страница 54: ...ion from the TSBC3000 Series to a Computer 3 2 2 Configuring the Terminal Emulator Application Before communicating with the management interface you must first configure a terminal emulator or consol...

Страница 55: ...oduct retrieve the TSBC3000 series product type See http docs telcobridges com mediawiki index php Get_Product_Type for further information tbserial retrieve the TSBC3000 series serial number See http...

Страница 56: ...working in conjunction with a TSBC3000 series 1 unit refer to Section 2 5 7 Start Up on page 32 To change the default configuration of a TSBC3000 series using the Web Portal follow the steps describe...

Страница 57: ...ps This section provides information about the following topics Section 4 1 Creating a Database Backup Section 4 2 Downloading a Database Backup Section 4 3 Uploading a Database Backup Section 4 4 Res...

Страница 58: ...backup be made once the system has been configured Backups are performed using the web portal 4 2 Downloading a Database Backup A backup of system data is stored on the hard drive of the TSBC3000 ser...

Страница 59: ...8C T1 E1 Wiring Schematic Crossover Cable 1 8 RX Ring 1 RX Tip 2 Not Connected 3 TX Ring 4 TX Tip 5 Not Connected 6 Not Connected 7 Not Connected 8 1 RX Ring 2 RX Tip 3 Not Connected 4 TX Ring 5 TX Ti...

Страница 60: ...ndalone and TSBC3000 Series 1 1 System Installation Guide 54 A 2 Tsbc Serial Adapter Wiring Diagram 1 N C 2 Rx 3 Tx 4 N C 5 GND 6 N C 7 N C 8 N C 9 N C 1 N C 2 N C 3 N C 4 GND 5 Tx 6 Rx 7 N C 8 N C DB...