Getting Started
b.
Change the AggregatorTrapDestination Port parameter to match
the port number on the Aggregator PC or server that will be used
to receive SNMP traps from monitored RFM220 instruments. You
should change this value only if your PC or server is already using port
162 for communication with other devices. The RFM220 Aggregator
will display an error message if it detects communication con
fl
icts
with other devices.
NOTE.
You will need to add the Aggregator Trap Destination and
Get/Set UDP port numbers to the Windows
fi
rewall exceptions on the
Aggregator PC or server to prevent communication problems between the
RFM220 Aggregator and any connected RFM220 Client. (See page 31,
Con
c.
Change the GetSetUDPPort parameter to match the port number on the
Aggregator PC or server that will be used for UDP communications
with the RFM220 Clients. You should change this value only of your
PC or server is already using port 161 for communication with other
devices. The RFM220 Aggregator will display an error message if it
detects communication con
fl
icts with other devices.
d.
Change the GetCommunityString and SetCommunityString parameter
values as desired. These values should not need to be changed unless
required by your network.
e.
Change the GetSetResponseTimeoutInms parameter value as
needed, based on the performance of your network. This is the
amount of time in milliseconds after which Get and Set command
communications with a monitored RFM220 instrument will time out
and a communication error message will be displayed.
26
RFM220 User Manual
Содержание RFM220
Страница 1: ...xx RFM220 ISDB Tb Measurement Demodulator ZZZ User Manual P071289600 071 2896 00...
Страница 2: ......
Страница 10: ......
Страница 22: ...Compliance Information xii RFM220 User Manual...
Страница 26: ...Preface xvi RFM220 User Manual...
Страница 100: ...Operating Basics 74 RFM220 User Manual...