Reference
Windows 7 Issues
Cannot edit the Con
fi
guration.xml
fi
le because it is read-only.
If you attempt to
edit the Con
fi
guration.xml
fi
le for the RFM220 Aggregator and you cannot
because the
fi
le is read only, there is likely one of the following permission
problems:
The
fi
le permissions were not set properly when the RFM220 software
was installed. In this case, reinstall the software as described for
Windows 7 systems. (See page 15,
Installing the RFM220 Software
The user who logged in does not have Full Access permissions. In this
case, right-click the RFM220 Aggregator and RFM220 Client icons and
select
Properties
. Set the access privileges. (See page 34,
The RFM220 application was not started using the “Run as Administrator”
command. In this case, stop the application, and then right-click the
application icon and select
Run as Administrator
.
Cannot access the RFM220 applications.
To operate the RFM220 software on
Windows 7 systems, observe the following:
Install the RFM220 software when you are logged on to the computer with
administrative privileges.
Ensure that the user who is logged onto the computer has Full Access
privileges for the RFM220 applications.
Start the RFM220 applications using the “Run as administrator” command.
RFM220 User Manual
87
Содержание RFM220
Страница 1: ...xx RFM220 ISDB Tb Measurement Demodulator ZZZ User Manual P071289600 071 2896 00...
Страница 2: ......
Страница 10: ......
Страница 22: ...Compliance Information xii RFM220 User Manual...
Страница 26: ...Preface xvi RFM220 User Manual...
Страница 100: ...Operating Basics 74 RFM220 User Manual...